RECOMMENDATIONS

• COSMO wine cellars are front venting but are not designed to be fully  

integrated behind a joinery door.

• COSMO wine cellars draw air from right of ventilation frame V 110 from the rear 

and expel through left of ventilation frame under the front door.

• COSMO wine cellars have a power switch located on the control panel so 

power point location is not critical.

• The power cord is (78.5 “/ 2.0m) in length and is fixed on the right side at the 

back when looking from front of cabinet.

•  As with most appliances of today, the wine cellar has sensitive electronic 

components which are susceptible to damage through lightning and 

electricity supply faults. It is therefore advised to use a power surge protector 

to avoid problems of this nature. 

• Air vent on door must be provided for built-in wine cellars when a wood door 

installed.

• In Hot climate zone, an air vent or grid, with a minimum ventilation size of 

7” x 1.57” MUST be cut out at the rear top of the back partitioning or at the top of 

either side of the partitioning, allowing cool fresh air full access to flow into the  

1 inch gap located at the rear of the cabinet. This air vent or grid must not be 

opened on the same side as other appliances such as ovens or an area that is 

sealed and without access to fresh cool air.

Failing to comply with the above specifications could result in WARRANTY void.

WINE

 

COOLER

WE

/

GN

WE

/

GN

OLP

Starter

E

L

N

OUT

 

Fan

LED

Sensor

 

1

Sensor

 

2

Heater

Optional

 

settings

Displsy

 

Board

PCB

Board

MODEL

:

IN

 

Fan

0

0

Rated

 

Frequenc y

Rated

 

Current

(

A

)

LED Lamp Power(W)

Refrigerant
Amount
Vesicant
Capacity

Electric  Shoc k

protection  Rating
Product Dimension

(WxDxH)
Manufacture  Date

60Hz

1

.

4A

0

.

8W

R600a

30g

Cyclopentan e

146L

I

605x600x87 0

COS-24BIWCS

 

BEFORE LOADING & PLUGGING IN THE WINE CELLAR

 Allow 24 hours before switching on the wine cellar. 

During this time we recommend that you leave the door open to clear any 

residual odors.

Important: All models without front venting (air opening) are strictly for free 
standing only. (See technical chart)

RECOMMENDATIONS:

The location you have selected for your wine cellar should:
• 

Be unencumbered and well ventilated.

• 

Be well away from any heat source and direct sunlight.

• 

Not be too damp (laundry, pantry, bathroom etc.).

• 

Have a flat floor.

• 

Have a standard and reliable electricity supply (standard socket to country 
standards, linked to the ground), it is NOT recommended to use a multi-sock-
et or extension lead.

• 

Have a surge protector fitted to the electrical outlet.

• 

Away from the microwave oven. Certain microwave ovens do not have 
wave interference shield. When placed within 1 meter vicinity of the wine 
cabinet, they may affect the operation of the wine cabinet. 

COSMO wine cellar should be placed where the ambient temperature is proper. 
If the temperature is above or below this range, it will affect the performance of 
the cellar. Placing in cold or hot temperature conditions may cause cellar’s tem-
peratures fluctuating, and it will not reach the ideal one.

GROUNDING INSTRUCTIONS:

COSMO wine cellar must be grounded in case of wire leakage. Grounding re-
duces the risk of electrical shock. The wine cellar is equipped with a power cord 
having a grounding wire and plug. The wine cellar plug must be plugged into a 
properly affixed and grounded electrical outlet.

Note: 

 In locations where there is frequent lightning, it is advisable to use surge 

protectors. Improper use of the grounding plug can result in the risk of electric 
shock. Consult a qualified electrician or service person if the grounding instruc-
tions are not completely understood.

If the supply cord is damaged, it must be replaced by a qualified person in order 
to avoid electrical hazard.

Summary of Contents for COS-24BIWCS

Page 1: ...s to improve the quality and performance of our products so we may make changes to our appliances without updating this manual COS 24BIWCS Wine Beverage Preservation Technology COS 24BIWCS PRODUCT MAN...

Page 2: ...le for any error in this manual is not responsible or liable for any spoil age or damage to wines or any other contents incidental or consequential to possible defects of the wine cellar Warranty appl...

Page 3: ...ant circuit Do not use extension cords or unground ed two prong adapters Children should be supervised to ensure that they do not play with the appliance If the supply cord is damaged it must be repla...

Page 4: ...BEFORE LOADING PLUGGING IN THE WINE CELLAR Allow 24 hours before switching on the wine cellar During this time we recommend that you leave the door open to clear any residual odors Important All mode...

Page 5: ...e wine cooler accessories 2 Inspect and remove any packing tape or printed materials 3 Before connecting the wine cooler to power source let it stand upright for approximately 24 hours This will reduc...

Page 6: ...Dryer filter Drop proof device Limit wheel Drop proof device pin 28 Lock base 29 Electrical power cord Canada 30 Water container 31 Compressor TU1110HY 115V 60HZ 32 PCB board 27 EXPLODED VIEW AND PAR...

Page 7: ...lar is designed with Auto cycle defrost system During Off cycle the refrigerated surfaces of the wine cellar defrost automatically Defrost water from the wine cellar storage compartment drains automat...

Page 8: ...4 six angle screwdriver 3 M4 door limit screw 4 Pincer 5 Door core 6 Slot type screwdriver 7 Upper door hinge 8 Lower door hinge 9 M5 six angle screwdriver 10 lower door hinge 11 Knife 1 1 1 11 2 2 2...

Page 9: ...r a long time there will be a few degrees variance between the temperature you have selected and the one indicated on the LED readout This is normal and it is due to the length of the activation time...

Page 10: ...ature inside the wine cellar and the actual temperature of the wine You will need to wait approximately 12 hours before noticing the effects of temperature adjustment due to the critical mass within a...

Page 11: ...lways unplug the unit before cleaning or performing mainte nance Never use harsh cleansers or scouring pads to clean any part of the unit Turn off the power unplug the appliance and remove all items i...

Page 12: ...For full warranty details on this product please visit http www cosmoappliances com warranty TO RECEIVE WARRANTY SERVICE YOUR PRODUCT MUST BE REGISTERED TO REGISTER VISIT WWW COSMOAPPLIANCES COM WARR...

Page 13: ...Electronic version of this manual is available at www cosmoappliances com...

Reviews: