INSTALLATION INSTRUCTIONS
Indoor unit installation
1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete,
or the like, use #8 anchor screws of
the appropriate size.
3. Fit the installation plate on the wall
with eight (8) anchor screws.
Note:
Fit the installation plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate is different
according to the models.
(Dimensions are in "mm" unless
otherwise stated)
Drill a hole in the wall
1. Determine hole positions according
to the diagram detailed in Fig.5. Drill
one (1) hole
(
2 ½”)
slanting slightly
to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate, or the like.
Correct orientation
of Installation Plate
Fig.4
150mm or more to ceiling
Indoor unit outline
150
90
Installation plate
120mm or
120mm or
more to wall
more to wall
Left rear side
Right rear side
refrigerant
refrigerant
pipe hole
Õ
65
900
pipe hole
Õ
Fig.5
Wall
Outdoor
Indoor
Fig.6