background image

3.4  Overvoltage protection

¡

Overvoltage protection circuit is built-in. If the overvoltage protec-
tion circuit is activated, shut down the input voltage, wait a certain 
time and turn on the AC input again to recover the output voltage.

  The recovery time is 3 minutes or more for TUNS300F/500F/700F, 

and 10 seconds or more for TUNS1200F. However, it varies de-
pending on such factors as input voltage value at the time of the 
operation.

Remarks:

Please note that devices inside the power supply might fail when 
voltage of more than rated output voltage is applied to output ter-
minal of the power supply.  This could happen when the customer 
tests the overvoltage performance of the unit.

3.5  Thermal protection

¡

When it exceeds the Derating, the thermal protection will be acti-
vated and simultaneously shut down the output.

  When the thermal protection is activated, shut off the input voltage 

and eliminate all the overheating conditions.  To recover the output 
voltage, keep enough time to cool down the power supply before 
turning on the input voltage again.

3.6 Remote ON/OFF

¿

TUNS300F/500F/700F

¡

Remote ON/OFF is not built-in.

¿

TUNS1200F

¡

Remote ON/OFF is built-in

¡

Remote ON/OFF is possible by applying a voltage between RC1 
and RC2 pin.

¡

When power supply shut off by over voltage protection or thermal 
protection, it can be recovered by toggling Remote ON/OFF 
signal.

¡

Remote ON/OFF circuit (RC1, RC2) is isolated from input, output, 
FG, AUX and various function terminals.

¡

Sink current of RC1 must be kept up to 12mA.

Table 3.1  Remote ON/OFF connection

No.

ITEM

RC1,RC2

1

Connection

method

Fig.3.1 (a)

Fig.3.1 (b)

Fig.3.1 (c)

2

Function

Output is ON in “L”

3

Isolation

INPUT - RC INPUT - RC

OUTPUT - RC INPUT - RC

4

Base pin

-S

RC2

-S, RC2

5

Output ON

SW OPEN

(0.1mA max)

SW SHORT

(0.5V max)

6

Output OFF

SW SHORT

(2mA min)

SW OPEN

(0.1mA max)

(c)

(a)

(b)

ON

POWER

RC2

RC1

AUX

OFF

-S

typ

12V

150Ω

1.1kΩ

ON

POWER

RC2

RC1

AUX

OFF

-S

typ

12V

150Ω

1.1kΩ

typ

12V

150Ω

1.1kΩ

ON

POWER

RC2

RC1 Rrc

V1

AUX

OFF

-S

Fig.3.1  Examples of connecting remote ON/OFF circuit

¿

-R1 (TUNS300F/500F/700F)

¡

Remote ON/OFF is possible by applying a voltage between RC1 
and RC2 pin. External DC power source is necessary to operate 
remote control.

  External current limiting resistor Rrc is necessary.

¡

When power supply shut off by over voltage protection or 

overheating protection, it can be recovered by toggling Remote 
ON/OFF signal.

Table .3.2  Remote ON/OFF connection specification

No.

ITEM

RC1, RC2

1

Function

Output is ON in “L”

2

Base pin

RC2

3

Output ON

SW OPEN 

(0.5V max, 0.1mA max)

4

Output OFF

SW SHORT 

(5mA typ, 3mA min)

¡

Sink current of RC1 must be kept up to 12mA.

RC1

150

RC2

12mA max

Rrc

OUTSIDE OF TUNS INSIDE OF TUNS

Vrc

SW

Vf

N

1.0V

Fig .3.2  RC Connection Example

*

Please be careful not to connect RC1 and RC2 opposite.

  It may cause a failure of power supply.

¡

Remote ON/OFF circuit (RC1, RC2) is isolated from the input and 
output and FG.

¿

-R2 (TUNS300F/500F/700F)

¡

”-R2” can reduce standby power than “-R1”.

¡

The usage is same as option “-R1”.

  Please refer to option “-R1”
■Standby power
  0.5Wtyp (AC100V), 1.2Wtyp (AC200V)

3.7  AUX for Remote ON/OFF circuit

¿

TUNS1200F

¡

The AUX can be used as the power source for Remote ON/OFF 
circuit.

¡

AUX is designed as shown in Fig.3.3, and a resistor (1.1kΩ ) is 
built in to protect the short circuit.Output voltage decreases as the 
output current increases.

12V typ

1.1kΩ

AUX

-S

Fig.3.3  AUX circuit

AC-DC Power Supplies Bus Converter.Power Module Type TUNS300F, TUNS500F, TUNS700F, TUNS1200F

Instruction Manual

TUNS-25

July 27, 2020

Summary of Contents for TUNS100F

Page 1: ...rallel operation 4 1 Series operation 4 2 Parallel operation 4 3 N 1 redundant operation 8 1 Medical Isolation Grade 5 Cleaning TUNS 22 5 Cleaning TUNS 30 TUNS 20 TUNS 20 TUNS 20 TUNS 21 TUNS 21 TUNS...

Page 2: ...C1 is not connected it may cause the failure of the power sup ply or external components Table 2 2 Input Capacitor C1 No Model Voltage Capacitance Rated ripple current 1 TUNS50F AC250V 1 F or more 3A...

Page 3: ...ore than recommended capacitance Table 2 4 Recommended capacitance Cbc No Model Voltage Cbc Allowable capacitance range 1 TUNS50F DC420V or more 82 F 47 to 150 F 2 TUNS100F 120 F 68 to 220 F 2 C2 Capa...

Page 4: ...e voltage is increased gradually When turning off reduce the voltage gradually by using the dial of the hi pot tester Do not use a voltage tester with a timer as it may generate voltage several times...

Page 5: ...ime expectancy depends on stress by temperature difference Regarding lifetime expectancy design of solder joint following contents must be considered It must be careful that the soldering joint is str...

Page 6: ...to 264Vin 3 F or more 5A or more 5 TUNS1200F 85 to 305Vin AC300V 3 F or more 5A or more 3 CY Noise filter Decoupling capacitor The product doesn t have noise filter internally Please connect external...

Page 7: ...current limiting resistor 4 7ohm 22ohm Connect a resistor between R pin and BC pin for inrush cur rent protection The surge capacity is required for TFR1 please contact component mfg Wirewound resisto...

Page 8: ...is ON in L 3 Isolation INPUT RC INPUT RC OUTPUT RC INPUT RC 4 Base pin S RC2 S RC2 5 Output ON SW OPEN 0 1mA max SW SHORT 0 5V max 6 Output OFF SW SHORT 2mA min SW OPEN 0 1mA max c a b ON POWER RC2 R...

Page 9: ...tage range the output ripple voltage might increase When the output voltage adjustment is not used open the VTRM pin 1 Output voltage adjustment by potentiometer By connecting the external potentiomet...

Page 10: ...e VTRM V Fig 3 9 VTRM Output Voltage TUNS1200F48 0 01 F 4 7k 10k VTRM S 5V Fig 3 10 VTRM circuit Y1 TUNS300F 500F 700F 1200F Adjustable voltage range of 48V output is changed to 20 Adjustable voltage...

Page 11: ...12 Power good PG TUNS1200F By using PG it is possible to monitor power supply whether normal operation or abnormal operation The PG signal is Low when the power supply operates correctly The signal tu...

Page 12: ...attaching the same heat sinks Connect the sensing line and the power line by one point after connecting each power supply s sensing pins S S If the output current is less than 2 of the rated current...

Page 13: ...Co R C1 F1 FG AC IN FG TFR1 CY C3 C2 BC M BC M Cbc AC1 AC2 VOUT VOUT Noise filter FG Co R C1 F1 FG FG TFR1 CY C3 C2 BC M BC M Cbc AC1 AC2 VOUT VOUT Noise filter FG Co R C1 F1 FG FG TFR1 CY C3 C2 BC M...

Page 14: ...for details 0 5 10 25 30 35 40 45 50 55 60 65 70 1time ON OFF 1day 2times ON OFF 1day 3times ON OFF 1day 4times ON OFF 1day 5times ON OFF 1day The aluminum base plate central temperature differenceDTc...

Reviews: