4.1 Series operation

¡

Series operation is available by connecting the outputs of two or 
more power supplies, as shown below. Output current in series con-
nection should be lower than the lowest rated current in each unit.

Power

supply

Power

supply

Power

supply

Power

supply

Load

Load

Load

(a)

(b)

Fig.4.1 Examples of series operation

4.2 Parallel operation/Master-slave operation

¡

Parallel operation is available by connecting the units as shown in 
Fig.4.2.

¡

As variance of output current drew from each power supply is 
maximum 10%, the total output current must not exceed the value 
determined by the following equation.

(Output current in parallel operation)
     =(the rated current per unit) 

X

 (number of unit) 

X

0.9

When the number of units in parallel operation increases, input 
current increase at the same time. Adequate wiring design for in-
put circuitry is required, such as circuit pattern, wiring and current 
capacity for equipment.

In parallel operation, the maximum operative number of units is 11.

Table 3.3 Recommended value of external potentiometer & resistor

No. Adjustable range [%] Number of unit

External parts value [

W

]

VR1

R1

R2

1

5

Single

5k

75k

1k

2

2sets

36k

3

3sets

24k

4

10

Single

5k

36k

910

5

2sets

18k

6

3sets

12k

(2) Adjusting method by applying external voltage

¡

By applying the voltage externally at TRM, output voltage become 
adjustable.

¡

Output voltage is calculated by the following equation.
(Output voltage)
     = (Applied voltage externally) 

X

 (Rated output voltage)

¡

The output adjustment range for DBS700B is shown in Fig.3.7.

Input Voltage [V]

200V

100

105

110

250

0

0

60

Output V

oltage [%]

Fig.3.7 DBS700B Output Voltage Adjustment Range

3.8 Isolation

¡

For a receiving inspection, such as Hi-Pot test, gradually 

increase(decrease) the voltage for a start(shut down). Avoid using 
Hi-Pot tester with the timer because it may generate voltage a few 
times higher than the applied voltage, at ON/OFF of a timer.

4 Series and Parallel

 Operation

DC-DC Converters Bus Converter

-

Power Module Type

Instruction Manual

DBS-17

June 26, 2020

Summary of Contents for DBS100A

Page 1: ...Thermal detection Thermal protection DBS 15 3 4 Inverter operation monitor DBS 15 3 5 Remote ON OFF DBS 15 3 6 Remote sensing DBS 16 3 7 Adjustable voltage range DBS 16 3 8 Isolation DBS 17 3 Function...

Page 2: ...external noise filter and a decoupling capacitor CY for low line noise and for stable operation of the power supply Install a correspondence filter if a noise standard meeting is re quired or if the...

Page 3: ...pins Table 2 2 Recommended capacitance Co F Model DBS100A DBS150A DBS200B DBS400B DBS700B Output voltage V 3 3 x 2200 6800 x 5 2200 2200 4700 x 7 5 x 2200 4700 x 12 1000 1000 2200 2200 13 8 1000 x x...

Page 4: ...hiccup operation of power supply 3 2 Overvoltage protection The overvoltage protection circuit is built in The DC input should be shut down if overvoltage protection is in operation The mini mum inter...

Page 5: ...current is drawn and the pattern may be damaged The pattern disconnection can be prevented by installing the pro tection parts as close as a load S S VOUT VOUT OUT Co Load Short at pin root Fig 3 4 C...

Page 6: ...ty for equipment In parallel operation the maximum operative number of units is 11 Table 3 3 Recommended value of external potentiometer resistor No Adjustable range Number of unit External parts valu...

Page 7: ...ration sensing wires should be connected between each units for the muster connection to a load Output current should be 10 or more of the total of the rated output current in parallel operation If le...