Cosel CHS12024 Instruction Manual Download Page 6

Table 4.1.2 Specification of Remote ON/OFF 

(CHS60,CHS120,CHS300,CHS380,CHS400,CHS500,CHS700)

ON/OFF 

logic

Between RC and -VIN

Output 

voltage

Standard Negative

L level(0 - 0.8V) or short

ON

H level(4.0 - 7.0V) or open

OFF

Optional -R

Positive

L level(0 - 0.8V) or short

OFF

H level(4.0 - 7.0V) or open

ON

When RC is ”Low” level, fan out current is 0.1mA typ. When Vcc is applied, 
use 4.0

[

Vcc

[

7.0V.

¡

When remote ON/OFF function is not used, please short between RC and 
-VIN (-R: open between RC and -VIN).

(2.0

[

Vcc

[

7.0V)

IC

Relay

Transistor

Photo coupler

RC

-VIN

RC

-VIN

RC

-VIN

RC

-VIN

Vcc

Fig.4.1 RC connection example

4.5 Remote sensing

(1) When the remote sensing function is not in use

+S

+VOUT

-S

Load

-VOUT

Short at pin root

Fig.4.2 Connection when the remote sensing is not in use

¡

When the remote sensing function is not in use, it is necessary to confirm 
that pins are shorted bS & +VOUT and between -S & -VOUT.

¡

Wire bS & +VOUT and between -S & -VOUT as short as pos-
sible.

  Loop wiring should be avoided.
  This power supply might become unstable by the noise coming from poor 

wiring.

(2)When the remote sensing function is in use

+S

Load

-S

+VOUT

-VOUT

Wire as close as possible

Fig.4.3 Connection when the remote sensing is in use

¡

Twisted-pair wire or shield wire should be used for sensing wire.

¡

Thick wire should be used for wiring between the power supply 

and a load.

  Line drop should be less than 0.3V.
  Voltage bVOUT and -VOUT should remain within the 

output voltage adjustment range.

¡

If the sensing patterns are short, heavy-current is drawn and the 
pattern may be damaged.

  The pattern disconnection can be prevented by installing the pro-

tection parts as close as possible to a load.

¡

Output voltage might become unstable because of impedance of 
wiring and load condition when length of wire exceeds 40cm.

4.6 Adjustable voltage range

(1) To adjust output voltage 

¡

Output voltage is adjustable by the external potentiometer.

¡

When the output voltage adjustment is used, note that the over 
voltage protection circuit operates when the output voltage is set 
too high.

¡

If the output voltage drops under the output voltage adjustment 
range, the Low voltage protection operates.

¡

By connecting the external potentiometer (VR1) and resistors (R1, 
R2), output voltage becomes adjustable, as shown in Fig.4.4.

  Recommended external parts are shown in Table 4.2.

¡

The wiring to the potentiometer should be as short as possible.

  The temperature coefficient could become worse, depending on 

the type of a resistor and potentiometer.  Following parts are rec-
ommended for the power supply.

 Resistor.............Metal film type, coefficient of less than ±100ppm/

C

 Potentiometer....Cermet type, coefficient of less than ±300ppm/

C

¡

When the output voltage adjustment is not used, open the TRM 
pin respectively.

¡

The change speed of the TRM voltage should be less than 0.15V/
ms.

CHS-33

DC-DC Converters Bus Converter.Power Module Type

Instruction Manual

Summary of Contents for CHS12024

Page 1: ...e converter 180 1 glassfabricbase epoxyresin Multilayer Yes 2 CHS12048 Half bridge converter 200 1 glassfabricbase epoxyresin Multilayer Yes 2 CHS200 Full bridge converter 150 1 glassfabricbase epoxyr...

Page 2: ...ing Input Output Pin CHS 31 3 1 Wiring input pin 3 2 Wiring output pin CHS 31 CHS 32 5 1 Series operation 5 2 Parallel operation 5 3 Redundancy operation CHS 35 CHS 35 CHS 36 6 1 Mounting method 6 2 A...

Page 3: ...Pin Connection and function No Pin Connection Function CHS60 CHS80 CHS120 CHS200 CHS300 CHS380 CHS400 CHS500 CHS700 1 1 VIN DC input 2 2 RC Remote ON OFF 3 3 VIN DC input 4 5 0 VOUT DC output 5 6 S R...

Page 4: ...al data Load VIN VIN RC FG DC input VOUT VOUT S S Fig 3 1 Recommended external input filter 4 Reverse input voltage protection Avoid the reverse polarity input voltage It will damage the power supply...

Page 5: ...Table 4 1 1 Specification of Remote ON OFF CHS80 CHS200 ON OFF logic Between RC and VIN Output voltage Standard Negative L level 0 0 8V or short ON H level 2 0 7 0V or open OFF Optional R Positive L...

Page 6: ...Line drop should be less than 0 3V Voltage between VOUT and VOUT should remain within the output voltage adjustment range If the sensing patterns are short heavy current is drawn and the pattern may...

Page 7: ...oltage becomes adjustable to decrease The external resistor RD is calculated by the following equation a Rated output voltage 10 15V RD 10 22 kW 5 11 b Rated output voltage 24V RD 2 kW 1 VOR VOD VOR V...

Page 8: ...1 Series operation Series operation is available by connecting the outputs of two or more power supplies as shown below Output current in series connection should be lower than the lowest rated curren...

Page 9: ...should not exceed the temperature range shown in derating curve Avoid placing the DC input line pattern layout underneath the unit It will increase the line conducted noise Make sure to leave an ample...

Page 10: ...nd VOUT shown in Fig 6 2 do not exceed the temperatures shown in Fig 6 3 If time or temperature of the reflow soldering goes beyond the conditions reliability of internal components may be compromised...

Page 11: ...nd the power supply might be damaged if the vacuum pressure is too much to reseal 6 7 Stress to the product CHS series transformer core and choke coil core are attached by glue There is a possibility...

Page 12: ...36 60V 4Others Vin 60 76V e CHS3804812 CHS3804812H Load factor 100 80 60 40 Temperature of measurement location C 40 20 0 20 0 20 40 60 120 100 80 3 2 1 4 2Option B Vin 60 76V 3Others Vin 36 60V 1Opti...

Page 13: ...t location CHS200 Temperature measurement location Fig 8 2 5 Temperature measurement location CHS300 Temperature measurement location Fig 8 2 6 Temperature measurement location CHS380 Temperature meas...

Page 14: ...Fig 8 3 Verify final design by actual temperature measurement Use the temperature measurement location as shown in Fig 8 2 1 to Fig 8 2 10 at 120C or less PWB 12 7mm Measurement point for ambient temp...

Page 15: ...8 9 Load current vs ambient temperature CHS804812 Vin 48V 40 30 20 10 0 10 20 30 40 50 60 70 80 90 1 2 3 0 5 10 15 20 25 30 1convection cooling 0 2m s 21m s 32m s Load current A Ambient temperature C...

Page 16: ...2m s Fig 8 21 Load current vs ambient temperature CHS3002415 Vin 24V 40 30 20 10 0 10 20 30 40 50 60 70 80 90 1 2 3 0 5 10 15 20 25 30 1convection cooling 0 2m s 21m s 32m s Load current A Ambient te...

Page 17: ...ig 8 29 Load current vs ambient temperature CHS4002415 Vin 24V 0 4 8 12 16 20 24 28 32 40 30 20 10 0 10 20 30 40 50 60 70 80 90 1convection cooling 0 2m s 21m s 32m s 1 2 3 Load current A Ambient temp...

Page 18: ...g 8 30 Load current vs ambient temperature CHS4002424 Vin 24V 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Ambient temperature C 0 5 10 15 20 25 30 35 40 45 1convection cooling 0 2m s 21m s 32m s 1 2 3 Lo...

Page 19: ...n a tray Fig 9 1 to Fig 9 3 Please order CHS60 S CHS80 S CHS120 S for tray type packaging Capacity of the tray is 15max In case of fractions the units are stored in numerical order Fig 9 1 Delivery pa...

Page 20: ...y package information CHS120 Dimensions in mm Material Conductive PS 38 33 2 38 323 136 23 37 5 62 4 248 38 33 2 38 323 136 23 37 5 62 4 248 CHS 47 DC DC Converters Bus Converter Power Module Type Ins...