background image

V151027

   

Biometrics Device Access controller 

Fingerprint

O. Alarm Clock (for Factory)

P. OpenZone

Q. Open TimeZone

Hardware installation

M1

Board

Horn

M2

1
2
3
4
5
6
7
8

N.C.

N.O.

COM

CTL

12V

ALM

12V

GND

GND

P1

Output to 

M1

 and 

M2

Mike device

Mike device

Music Box

Music Box

Mike's sound wire

Mike's sound wire

DC 12V Relay Board

Controller 

POWER

12VDC

Access programming mode

 →     

Tools

 →     

Daily Alarm

 → 

Set (00~15) 

→ 

Set Start Tm (24 Hours)

 

;

 

Set Effect Sec. 

(Seconds as the bell time, Range:1~255)

 

→ 

Set Weekday (0:disable, 1: enable) 

→ 

Succeeded

  

5

9

Access programming mode

 →     

Parameters[1]

 →     

OnOff OpenZone

 → 

Main Controller Auto Open Zone

 

(0:disable,1:enable) 

→ 

Open Door Imm. During Open Zone

 

(0:No,1:Yes)

 → 

WG1 Port Auto Open Zone (0:disable,1:enable) 

 

Open Door Imm. During 

Open Zone

 

(0:No,1:Yes)

 → 

Succeeded

  

3

2

N. Lift control

[e.g.] Connect with 

Lift Controller

 to control which floors the user will be able to access. (BAUD9600)

Access programming mode

 →     

Tools

 →    

 Terminal Port

 → 

0

Lift Controller 

→ 

Baud Selection 0

: 

9600

5

4

Setting Lift control

Access programming mode

 →     

User Setting

 →    

 Single Floor

 →

Input 5-digit user address

 → 

Input single floor number: 1~64

2

4

Single floor

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

Input 5-digit user address

 → 

Select range: 1 or 2 or 3 or 4

 → 

Input 16 digits 

multi floors number [0:disable, 1: enable]

[e.g.] Set NO. 114, can use it with the 8 F and 16F:

       

Access programming mode

 →     

User Setting

 →    

 Multi Floor

 → 

114

     

 

→ 

1     

 

→ 

0000000100000001

           

2

2

5

5

Multi floors

Set Floor/ Stop

1

0

17

0

33

0

49

0

9

0

25

0

41

0

57

0

1

2

3

4

3

0

19

0

35

0

51

0

11

0

27

0

43

0

59

0

2

0

18

0

34

0

50

0

10

0

26

0

42

0

58

0

4

0

20

0

36

0

52

0

12

0

28

0

44

0

60

0

5

0

21

0

37

0

53

0

13

0

29

0

45

0

61

0

6

0

22

0

38

0

54

0

14

0

30

0

46

0

62

0

7

0

23

0

39

0

55

0

15

0

31

0

47

0

63

0

8

1

24

0

40

0

56

0

16

1

32

0

48

0

64

0

Access programming mode

 →     

Tools

 →    

 Terminal Port

 → 

1

Lift Controller

(

need to use 725L485

)

5

5

Access programming mode

 →     

Tools

 →     

Open TimeZone

 → 

Set (00~15) 

→ 

Time

 

(24

 

Hours)

 

;

 

Main Port (0:disable, 1: enable) ; 

WG Port (0:disable, 1: enable) 

→ 

Weekday

 

(0:disable, 1: enable)

 → 

succeeded 

 

5

6

M. Anti-pass-back

Device enable

Access programming mode

 →   

 

 

Parameters[2]

 →     

Anti-pass-back

 → 

master controller select [1: Yes] 

→ 

WG select [1: Yes]

4

6

Card user enable

Access programming mode

 →   

 

 

Add/ Delete

 →     

Antipass Group

 → 

Input 5-digit starting user address

 → 

Input 5-digit ending user 

address

 → 

must select [1: Yes]

1

9

Summary of Contents for COR-ACC995-V2

Page 1: ...igger Input Alarm Relay 6 Gray Transistor Output Max 12V 100mA Open Collector Active Low Power 7 Thick Red DC 12V 8 Thick Black DC 0V Cable P1 WireApplication Wire Color Description RS 485 for Lift Controller 1 Thick Green RS 485 B 2 Thick Blue RS 485 A Cable P4 WireApplication Wire Color Description 1 2 TCP IP Output 3 Orange White Net TX 4 Orange Net TX 5 Green White Net RX 6 Green Net RX 7 P3 C...

Page 2: ...incorrect pin code or master code 4 Maximum error in ut of pin code and master code can be changed via the software 701Server default 5 times Power Green Alarm Red Alarm Green OK Green Error Red In processing Green Networking and interactively flash between the Month and DAY e g 12 07 12 07 Stand alone No flashing e g 12 07 Reference to picture Connect to Electric Bolt Wiring Diagram EXIT 1 2 3 4 ...

Page 3: ...TE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Electric Strike Door Contact Strengthen security with ACC 899 If any fire emergency the people can escape by press a switch to open all doors Electric Bolt Electric Bolt Electric Bolt Fire Emergency Transistor IN4007 Transistor IN4007 Connect to Reader Magnet Lock Connect to Electric Strike Connect to Do...

Page 4: ...ogramming mode 7 Access programming mode Add Delete Add RF Learn Input 5 digit user address Input Tag Units pcs Close Tag into RF Area If a batch of tags are Sequential input Tag Units pcs in the quantity of the tags and present the tag with the lowest number to the controller 1 2 Adding Tag by RF Learn Function Tag Information SITE CODE CARD CODE SITE CODE CARD CODE User capacity 16384 00000 1638...

Page 5: ... Arming 7 Disable Access programming mode Quit 6 No open the door Input 4 digits arming PWD Present the tag to reader Access programming mode Parameters 1 ArmingDelayTm Enter armed sta Delay time Sec Range 000 255 Armed pulse out put time 10ms Range 000 255 Succeeded 3 7 Use FP can substitute for Induct valid card F Adding Deleting Fingerprint or Finger Vein Adding Access programming mode User Set...

Page 6: ...git user address Input single floor number 1 64 2 4 Single floor Access programming mode User Setting Multi Floor Input 5 digit user address Select range 1 or 2 or 3 or 4 Input 16 digits multi floors number 0 disable 1 enable e g Set NO 114 can use it with the 8 F and 16F Access programming mode User Setting Multi Floor 114 1 0000000100000001 2 2 5 5 Multi floors Set Floor Stop 1 0 17 0 33 0 49 0 ...

Page 7: ...y Tm 7 Arming Delay Tm 8 Arming PWD 2 User Setting 1 Password 2 Access Mode 3 Extend Options 4 Single Floor 5 Multi Floor 6 Enroll Finger 7 Delete Finger 1 Add Delete 1 Add Card ID 2 Add RF Learn 3 Suspend Address 4 Suspend ID 5 Delete Address 6 Delete ID 7 Recover Address 8 Recover ID 9 Antipass Group Reset all device parameters and user card data Access programming mode Parameters2 Factory Reset...

Page 8: ...same as sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password composes of 10 characters at most it can be either A Z or 0 9 Change the log in password to lock the IP setting of Ethernet Module If the IP address of ACC995 V2 has changed We must enter the ne...