Cortex COR-ACC900 Manual Download Page 3

COR-ACC900

Time Attendance
Auto Re-lock
Auto Open
Exit by Push Button
Master Reader of Network
Access/Exit Reader 
Anti-pass-back 

Yes*

Disable*
Disable*

Disable

Slave*

Exit*

Disable*

No

Enable
Enable

Enable*

Master

Access

Enable

001
002
004
016
032
064
128

Networking

Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone

Networking
Networking
Networking

Function

Option

0

1 Value

Application

Function

Option

0

1

Value Application

Function Default Value

Programming

A

20*DDD#

Remarks:

*

default value

Option

 0= none value

Option

 1= 1 

each value (i.e. DDD value of Enable “Auto Open” + 

”Exit by Push ”Anti-pass-back” =004+016+128=148; 
As a result, the command will be 20*148# .)

B

24*DDD#

Auto-open door without 

presenting card at auto 

open zone

Alarm Output*

Stop Alarm by…

Door bell

Alarm Output/Lift Control

064

128

001

002

Networking /

Stand-Alone
Networking /

Stand-Alone

Networking /

Stand-Alone

Networking /

Stand-Alone

Networking / 

Stand-Alone

Push Button / 

Door Closed

Enable

Lift Control

Enable

None*

Disable*

Disable*

Function

Option

0

1

Value Application

C

28*DDD#

Force Open  Alarm 

Output

Disable*

Enable

128

A

Entering and Exiting Programming Mode

Entering    

                                                         Exiting 

*123456#  or  *Master Code#

  

(If already changed) 

  

#

B

Initial Setup

  1.Restoring Factory Settings

       Access programming mode

 

 *123456# 

 

or 

 

*Master Code#  

      (If already changed) 

→ 

 20*000# 

  →   

24*000#  

→  

     26*00000*01023*2#  

→ 

 28*000# 

 →  

29*29*# 

 →

 Changing 

      the Master Code to default value:123456→  

*# 

 (done)

C

Setting up the control mode (M4/M6/M8)

     

  

 Access programming mode 

 

*123456# 

 or  

*Master Code# 

 personal ID 

(If already changed) 

         →  

04*N#

   (Input: 4/6/8)

    

   1.Individual PWD (M4/M8)

           

a

.

Card or PIN

                

Access programming mode 

 

*123456#

 

 or

  

*Master Code#  

      

           (If already changed)

 →  

12*UUUUU*PPPP#

 

 (i.e. User 

                  address: 00001 and PWD: 1234, input 12*00001*1234#)

 2.Changing the Master Code

     Access programming mode

  

*123456# 

 or 

 

*Master Code#  

     (If already changed)

 →  

09*PPPPPPRRRRRR# 

 

(Input the 

     6-digit new master code twice)

3.Changing the Node ID of Reader

    Access programming mode

  

*123456#

  

or

 

 *Master Code# 

    (If already changed)

 → 

00*NNN# 

 

(Node ID: 001~254)

    b

.

Card and PIN

          Access programming mode 

 

*123456# 

 

or  

*Master Code# 

 

         (If already changed) 

→ 

 13*UUUUU*PPPP# 

 (i.e. User address: 

         00001 and PWD: 1234, input 13*00001*1234#)

2.Public PWD (M6)

    a

.

Card and PIN 

          Access programming mode

 

 *123456# 

 or 

 

         *Master Code# 

 

(If already changed)  

→  

17* PPPP#

  

          (Input 4-digit PWD, default value: 1234)

    b

.

PIN only 

          Access programming mode 

 

*123456# 

 or

  

         *Master Code#

  

(If already changed)

  →  

15* PPPP# 

 

          (Input 4-digit PWD)

E

Anti-pass-back

Usually, anti-pass-back is commonly applied to parking areas or 
elsewhere user wants to monitor not only the access but also exit 
condition.
  Enable device 
     Access programming mode 

→ 

 20*128# 

 please refer to “20*DDD#”

     function default value for additional function value

  Enable card user 
     Access programming mode

 →  

26*SSSSS*EEEEE*0# 

   

    (i.e. User  address from 00001 to 00005 enable the anti-pass-back 
    function:   26*00001*00005*0# 

F

Auto Open Zone

Door will remain opening after first person flashes card.  ACC900 only supports two sets 

of auto-open zone by device setting, but auto-open zone can be extended up to 63 sets if 

connected to ACC1000.

   Enable/Disable auto open zone

     Access programming mode  

 

20*004#

  please refer to “20*DDD#” function default value for 

     additional function value 
  

 Enable/Disable auto open door without presenting card

     Access programming mode   

24*001#

  

please refer to “24*DDD#” function default value for 

     additional function value 
   

Setting up open time

     Access programming mode →  

08*N*HHMMhhmm*01111100# 

     N: 

2 sets of auto-open zone (N=0=1st set; N=1=2nd set)

     HHMMHHMM=

staring time to ending time (i.e.: 08301200=08:30 to 12:00)

D

Setting up the password

(Default Value)

V150911

Summary of Contents for COR-ACC900

Page 1: ...e Orange Purple Grey Thick Red Thick Black N C N O RS232 RS 485 or USB RS 485 Converter MagneticDoorContacts Magnet Lock Bolt Lock PushButton StrikeLock Contact Rating 1A125VAC 24VDC Do not connect the reader and lock to the same power supply Lock activation may cause reader power instability and might affect the reader function The door relay and the lock use the same power supply when applying a...

Page 2: ...address EEEEE Ending user address 11 SSSSS EEEEE SSSSS Starting user address EEEEE Ending user address 12 UUUUU PPPP UUUUU User address PPPP 4 digit individual PWD 13 UUUUU PPPP UUUUU User address PPPP 4 digit individual PWD 14 TTT Arming output time 001 250 1 250 sec 15 PPPP PPPP 4 digit individual PWD P S Duress code will be unavailable and become a public PIN at access mode Card or PIN of M6 16...

Page 3: ...00001 and PWD 1234 input 12 00001 1234 2 Changing the Master Code Access programming mode 123456 or Master Code If already changed 09 PPPPPPRRRRRR Input the 6 digit new master code twice 3 Changing the Node ID of Reader Access programming mode 123456 or Master Code If already changed 00 NNN Node ID 001 254 b Card and PIN Access programming mode 123456 or Master Code If already changed 13 UUUUU PPP...

Page 4: ...eting Tag M6 M6 Accessprogramming mode 123456 or MasterCode Ifalreadychanged 11 SSSSS EEEEE SSSSS startinguser address 5 digitcardcode EEEEE endinguser address 5 digitcardcode i e Addatagwithcard code15031 11 15031 15031 i e Addabatchoftag withcardcode 15031 15038 11 15031 15038 Done Accessprogramming mode 123456 or MasterCode Ifalreadychanged 10 SSSSS EEEEE or 10 SSSSS9EEEEE SSSSS startinguser ad...

Reviews: