![Cortex COR-ACC900 Manual Download Page 3](http://html.mh-extra.com/html/cortex/cor-acc900/cor-acc900_manual_2669957003.webp)
COR-ACC900
Time Attendance
Auto Re-lock
Auto Open
Exit by Push Button
Master Reader of Network
Access/Exit Reader
Anti-pass-back
Yes*
Disable*
Disable*
Disable
Slave*
Exit*
Disable*
No
Enable
Enable
Enable*
Master
Access
Enable
001
002
004
016
032
064
128
Networking
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking
Networking
Networking
Function
Option
0
1 Value
Application
Function
Option
0
1
Value Application
Function Default Value
Programming
A
、
20*DDD#
Remarks:
*
:
default value
Option
0= none value
Option
1= 1
x
each value (i.e. DDD value of Enable “Auto Open” +
”Exit by Push ”Anti-pass-back” =004+016+128=148;
As a result, the command will be 20*148# .)
B
、
24*DDD#
Auto-open door without
presenting card at auto
open zone
Alarm Output*
Stop Alarm by…
Door bell
Alarm Output/Lift Control
064
128
001
002
Networking /
Stand-Alone
Networking /
Stand-Alone
Networking /
Stand-Alone
Networking /
Stand-Alone
Networking /
Stand-Alone
Push Button /
Door Closed
Enable
Lift Control
Enable
None*
Disable*
Disable*
Function
Option
0
1
Value Application
C
、
28*DDD#
Force Open Alarm
Output
Disable*
Enable
128
A
、
Entering and Exiting Programming Mode
Entering
Exiting
*123456# or *Master Code#
(If already changed)
*
#
B
、
Initial Setup
1.Restoring Factory Settings
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
20*000#
→
24*000#
→
26*00000*01023*2#
→
28*000#
→
29*29*#
→
Changing
the Master Code to default value:123456→
*#
(done)
C
、
Setting up the control mode (M4/M6/M8)
Access programming mode
*123456#
or
*Master Code#
personal ID
(If already changed)
→
04*N#
(Input: 4/6/8)
1.Individual PWD (M4/M8)
a
.
Card or PIN
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
12*UUUUU*PPPP#
(i.e. User
address: 00001 and PWD: 1234, input 12*00001*1234#)
2.Changing the Master Code
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
09*PPPPPPRRRRRR#
(Input the
6-digit new master code twice)
3.Changing the Node ID of Reader
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
00*NNN#
(Node ID: 001~254)
b
.
Card and PIN
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
13*UUUUU*PPPP#
(i.e. User address:
00001 and PWD: 1234, input 13*00001*1234#)
2.Public PWD (M6)
a
.
Card and PIN
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
17* PPPP#
(Input 4-digit PWD, default value: 1234)
b
.
PIN only
Access programming mode
*123456#
or
*Master Code#
(If already changed)
→
15* PPPP#
(Input 4-digit PWD)
E
、
Anti-pass-back
Usually, anti-pass-back is commonly applied to parking areas or
elsewhere user wants to monitor not only the access but also exit
condition.
Enable device
Access programming mode
→
20*128#
please refer to “20*DDD#”
function default value for additional function value
Enable card user
Access programming mode
→
26*SSSSS*EEEEE*0#
(i.e. User address from 00001 to 00005 enable the anti-pass-back
function: 26*00001*00005*0#
F
、
Auto Open Zone
Door will remain opening after first person flashes card. ACC900 only supports two sets
of auto-open zone by device setting, but auto-open zone can be extended up to 63 sets if
connected to ACC1000.
Enable/Disable auto open zone
Access programming mode
20*004#
please refer to “20*DDD#” function default value for
additional function value
Enable/Disable auto open door without presenting card
Access programming mode
24*001#
please refer to “24*DDD#” function default value for
additional function value
Setting up open time
Access programming mode →
08*N*HHMMhhmm*01111100#
N:
2 sets of auto-open zone (N=0=1st set; N=1=2nd set)
HHMMHHMM=
staring time to ending time (i.e.: 08301200=08:30 to 12:00)
D
、
Setting up the password
(Default Value)
V150911