COR-ACC900
COR-ACC900
Entering programming mode
Exiting programming mode
Exiting programming mode and
enabling arming status
Node ID setting (Connect to ACC1000)
Node ID setting (Connect to PC Directly)
Door relay time setting
Control mode setting
Arming delay time setting
Alarm delay time setting
Suspend or delete tag
(*=Suspend)
(9=Delete)
Setting up a batch of user to
access by card only
(M6 only)
Setting up the PWD/PIN
(Access mode: Card or PIN)
Setting up the PWD/PIN
(Access mode: Card and PIN)
Arming output time setting
M4/M8: Duress code setting
M6: Public PIN setting
(Card or PIN)
M4/M8: Arming PWD setting
M6: Public PIN setting
(Card and PIN)
Door close time
Adding tag
Factory setting-1
(Function default value)
Add/Delete tag by RF
(M6 only)
Relay time of lift controller setting
Factory setting-2
(Function default value)
Real time clock setting
(Stand-Alone)
Lift control setting: single door
Force open alarm setting
Delete all tag
Same Tag reading interval time
*123456#
or
*Master Code#
(If already changed)
* #
00*NNN#
(Node ID: 001~254)
02*TTT#
(Door relay time: 000=Normal open) (Door relay time: 001~600=1~600 sec.)
(Door relay time: 601~609=0.1~0.9 sec.)
03*TTT#
(Door relay time: 000=Normal open)
(Door relay time: 001~600=1~600 sec.)
04*N#
(Mode: 4/6/8)
05*TTT#
(Arming delay time: 001~600=1~600 sec.)
06*TTT#
(Alarm delay time: 001~600=1~600 sec.)
07*SSSSS*EEEEE#
(Input a user or a batch of user as the master card: 00000~01023)
SSSSS
=Starting user address
,
EEEEE
=Ending user address
08*N*HHMMhhmm*1111111#
N:
2 sets of auto-open zone (0: 1st set; 1: 2nd set)
HHMMhhmm
=Staring time to ending time (i.e.: 08301200=08:30 to 12:00)
01111100:
Sun./Mon./Tue./Wed./Thu./Fri./Sat./Holiday (0: disable; 1: enable)
09*PPPPPPRRRRRR#
PPPPPP
=New master code
RRRRRR
=Repeat the new master code
Suspend:
10*SSSSS*EEEEE#
Delete:
10*SSSSS9EEEEE#
SSSSS
=
Starting user address
,
EEEEE
=
Ending user address
11*SSSSS*EEEEE#
recover the paused tag
SSSSS
=
Starting user address
,
EEEEE
=
Ending user address
11*SSSSS*EEEEE#
SSSSS=
Starting user address
,
EEEEE=
Ending user address
12*UUUUU*PPPP#
UUUUU
=
User address
PPPP
=4-digit individual PWD
13*UUUUU*PPPP# UUUUU
=
User address
PPPP
=4-digit individual PWD
14*TTT#
(Arming output time: 001~250=1~250 sec.)
15* PPPP#
PPPP
=4-digit individual PWD
P.S. Duress code will be unavailable and become a public PIN at access mode “Card or PIN” of M6
16*UUUUU*SSSSSCCCCC#
UUUUU
= User address
,
SSSSS
=5-digit site code
CCCCC
=
5-digit card code
17* PPPP#
PPPP
=4-digit individual PWD ( default value=1234; disable Arming PWD=0000)
P.S. Arming PWD code will be unavailable and become a public PIN at access mode “Card PIN” and of M6
18*TTT#
(Door close time: 001~600=1~600 sec.; default value: 15 sec.)
19*UUUUU*QQQQQ#
UUUUU
=User address
,
QQQQQ
=
Pieces of card
20*DDD#
(Please refer to function default value for details)
21*UUUUU*S*FFFFFFFF#
UUUUU
=
User address
S
:
4 sets of lift control (Input: 0~3)
,
FFFFFFFF
:
8 floors/stop setting (0=Disable, 1=Enable)
22*N# N
=0=Delete tag
,
N
=1=Add tag
23*NNN*TTT#
N
=Node ID of lift controller
,
TTT
= relay time: 000~600=1~600 sec.
24*DDD#
(Please refer to function default value for details)
25*YYMMDDHHmmSS#
YYMMDDHHmmSS:
Year/Month/Day/Hour/Min./Sec.)
26*SSSSS*EEEEE*N#
SSSSS
=Starting user address
,
EEEEE
=
Ending user address
N
=
0=Enable;
N
=1=Disable;
N
=2=Initial
27*UUUUU*FF#
UUUUU
=
User Address
,
FF
=
Floor number (01~32 floor/stop)
28**NNN# NNN
=000=Disable
,
NNN
=128=Enable
29*29*#
31*TTTT# TTTT
=0100=1 Sec. (Base on 10ms, TTTT range from 10~6500=0.1-65 sec.)
Master card setting
Auto-open zone setting
Recover tag
Card number modification
Lift control setting: multi-doors
Anti-pass-back
(Enable user)
Master code setting
Alarm relay time setting
M6
M6
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M8
M4/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
Command List
* * #
00*NNN*VVV*nnn#
(NNN: Node ID) (VVV: Virtual ACC Node ID) (nnn: Door Number)
Ex.: Input 00*002*002*002# for 2nd door in system
V150911