Starting and settings
Make sure that the installation is completely finished before the current is connected to the control
unit. The control panel is used for settings and test operation so connect it temporarily to an AC
adapter close to the installation in the attic. More information about menu selections and settings
can be found in the manual:
HomeVision PRO control panel
.
Once the settings have been made, the system automatically shifts to normal operating mode and
the fan is then controlled by the current climate.
Connect the control panel to the control unit
The control unit is open for connection for 2 minutes after the control unit is powered. After 2
minutes, connection to the control panel is no longer possible, and the control unit must be restarted
by disconnecting the current for a short period.
Setting date and time
Set the correct date and time via the control panel. In order for the timeline in the log that is stored
on the USB memory to be easy to read, the date and time should always be checked and set as
necessary. If the control unit is unpowered for longer than 24h the date and time must be reset.
Select correct type of fan
VentoVind PRO Special has an AC type fan installed upon delivery. Always check which fan type is
selected in the menu on the control panel. If the incorrect fan type is selected, the VentoVind system
will not work.
Activating Tacho signal (Any point)
To obtain feedback about the EC fan speed and receive an alarm in the event of an operational stop,
activate Tacho in the menu on the control panel. Set the lowest possible speed 100rpm/min as alarm