put into operation as required, i.e. only when drying with adaptive ventilation is not able to lower the
humidity below the set level. Only Corroventa dehumidifiers intended for fixed installations in cold
attics are recommended for this type of installation.
Delivery check
VentoVind
TM
special control unit is supplied with the following parts:
Control unit VentoVind
TM
1 x
Outdoor sensor, with separable 15m cable
1 x
Indoor sensor, with 15m cable
1 x
Control panel HomeVision
1 x
Current adapter control panel
1 x
Mounting screws for control unit and sensor
8 x
User instructions
1 x
Operation & maintenance instructions
1 x
Plastic pouch + operation & maintenance instructions
1 x
Other component parts such as fan, dampers and other installation parts adapted according to each
installation and number as well as dimensions are stated on the delivery note that accompanies the
delivery.
Installation
Note that any electrical installations carried out in connection with this work must be
done by a qualified electrician in accordance with local and national regulations.
VentoVind™ must be connected to an earthed, single phase 230 VAC/50 Hz socket.
The socket must be fused with a protection fuse up to 16A and an earth-fault breaker
is recommended. Relevant protective equipment and protective clothing must be used
in accordance with the employer's regulations/applicable local work environment plan
AFS2012:02 AFS1981:14.
VentoVind
TM
is installed and assembled in the following steps.
Step 1: Plan thoroughly so that an adequate air exchange can occur in the cold attic.
Step 2: Connections to outdoor air and connection of electricity.
Step 3: Thorough sealing of the attic.
Step 4: Assemble the equipment.
Step 5: Starting and test operating the installation.
Planning the installation
Thorough planning of the installation is a condition for a good result. Each installation is unique and a
universal installation principle cannot be specified. Depending on how much attic space is to be