c) Construction internal

Electrical equipment is located in an internal distribution box and the rotor unit is attached to 

this by a quick release connector. The rotor unit contains the rotor (6), drive motor (7), drive 

belt (8), heating element (15) and covers (12,13), that is to say all internal components close to 

the fan (3). 

The parts referred to in the schematic images are described in more detail below.

(5) 

 Elastically secured removable ”drying pack”

(6) 

 Drying rotor with hub, bearing, spokes and blades

(7) 

 Drive motor with pulley for drive belt

(8) 

 Toothed drive belt

(9) 

 Rotor seal that forces air to pass through the drying rotor

(10) 

 Process air fan. There is a grille and filter between the  process air fan and the process 
air inlet (3)

(12) 

 Heat cover that traps part of the process air for regeneration of the drying rotor

(13) 

 Collection cover for wet air

(15) 

 Heating element

(20) 

 Rotor stay to secure the rotor in the drying pack. The rotor shaft is secured in the 
middle of the rotor stay

(21) 

 Bent panel to facilitate air flow and thereby reduce flow losses

- 4 -

5

12

20

9

13

21

6

7

15

8

17

10

3

Summary of Contents for CTR 500TT

Page 1: ...ss Contact person Tel no 201711 Technology and products for remediation of radon moisture and odours TECHNICAL DESCRIPTION DEHUMIDIFIERS FOR CRAWLSPACES CTR 500TT Developed and manufactured by Corrove...

Page 2: ...ifier CTR 500TT a Function b Construction external c Construction internal d Control panel 4 Technical data for dehumidifier CTR 500TT 5 Installation a Location of CTR 500TT b Duct system c Connection...

Page 3: ...ode at 60 RH At 70 RH there is a risk of moulding A rule of thumb is that 50 RH is a good climate for most materials But in the North it is rarely 50 RH In most places in the Nordic countries the aver...

Page 4: ...s desiccant with a total drying aera of approx 600 000 m2 The dehumidifier is used to dry atmospheric air using the adsorption principle The adsorption rotor The rotor has axially directed air ducts a...

Page 5: ...rthed plug for connection to an earthed 220 V socket 1 phase alternating current 50Hz Hygrostat socket that fits Corroventa s own control panel Run time meter that registers the time when the dehumidi...

Page 6: ...ack 6 Drying rotor with hub bearing spokes and blades 7 Drive motor with pulley for drive belt 8 Toothed drive belt 9 Rotor seal that forces air to pass through the drying rotor 10 Process air fan The...

Page 7: ...ad in the crawl space is too great a red lamp lights A green lamp also lights as long as the ventilation in the crawl space is functioning If the ventilation does not function because the fan does not...

Page 8: ...oval of wet air simple electrical connection space and access for easy filter changes The dehumidifier is installed in the area to be dehumidified It is ideally positioned near a wall on a bracket or...

Page 9: ...indicator box The indicator box must be placed in a suitable location in the house where it can be easily monitored To avoid unnecessary electrical routing it should be as close to the dehumidifier hy...

Page 10: ...panel to light Allow the machine to cool and pull the electrical plug out of the socket If the machine has stopped because of a dirty filter it will run again after replacing the filter once the plug...

Page 11: ...Install the hygrostat section with connection box 6 Route the according to point 2 above disconnected cable up through the drilled hole to the upper floor 7 Screw the indicator box into place at a sui...

Page 12: ...Technology and products for remediation of radon moisture and odours CORROVENTA AVFUKTNING AB Mekanikerv gen 3 SE 564 35 Bankeryd Tel 46 0 36 37 12 00 mail corroventa se www corroventa se...

Reviews: