X75 Fusion Splicer
Preparatiss
Operating Instructions
revision: 06/01
2-5
Cleaning the
Fiber
Clean the fiber ends over a length of approx. 100 mm (coating and uncoated fiber) with a
lint-free paper towel dampened with alcohol.
DANGER
Risk of fire exists if solvents are spilled.
Cleaving the
Fiber
Use a suitable cleaver, e.g. cleaver S46999-M9-A8, to cleave the fiber. Select the correct
fiber guides for the cleaver (Fiber Optic Cleaver A8: Universal fiber guide for 250 to 900
µ
m
coating diameter).
-
Open the flap (pos. 4) at the cleaver and lay the fiber with coating diameter 250
µ
m into
the cleaver such that the end the coating is aligned with the “10 mm” mark. With coating
diameters greater than 250
µ
m align with the mark at 15.
1
2
3
1 Cleave length: 10 mm (250
µ
m)
or 15 mm (>250
µ
m)
2 Uncoated fiber
3 Coating
4
Summary of Contents for X75 8000 Series
Page 8: ......
Page 18: ...Operating Instructions revision 06 01 X75 Fusion Splicer X75 Fusion Splicer Overview 1 8 ...
Page 58: ...Operating Instructions revision 06 01 X75 Fusion Splicer Splicing 4 10 ...
Page 82: ...Operating Instructions revision 06 01 X75 Fusion Splicer Supplements Changes Notices 7 2 ...
Page 83: ...X75 Fusion Splicer Supplements Changes Notices Operating Instructions revision 06 01 7 3 ...
Page 84: ...Operating Instructions revision 06 01 X75 Fusion Splicer Supplements Changes Notices 7 4 ...