Safety Precautions 

Never

 use the microcentrifuge in any manner not specified in these 

instructions. 

Never

 operate the microcentrifuge without a rotor properly attached to 

the shaft. 

Never

 fill tubes while they are in the rotor. Liquid spillage may harm the 

unit. 

Never

 put hands in the rotor area unless the rotor is completely stopped. 

Never

 move the microcentrifuge while the rotor is spinning.

Never

 use solvents or flammables near this or other electrical equipment. 

Never

 centrifuge flammable, explosive, or corrosive materials. 

Never

 centrifuge hazardous materials outside of a hood or proper 

containment facility.

Never

 try to continue operating the microcentrifuge if the microcentrifuge 

stops working prematurely. Stop the microcentrifuge immediately by  
turning off the main power switch on the back side of the microcentrifuge. 
Wait one minute before turning on the main power switch to operate the 
microcentrifuge again.

Always

 load the rotor symmetrically. Each tube should be counter balanced 

by another tube. Weight of individual tubes may not exceed 3.0 g. 

Always

 place the microcentrifuge within easy access to an electrical outlet. 

Always

 use only microcentrifuge tubes made from plastic and designed 

to withstand centrifugal forces of at least 2,000 x g.

Cleaning

Before using any cleaning or decontamination methods other than those 
recommended by the manufacturer, check with the manufacturer that 
the proposed method will not damage the equipment. To clean the micro-
centrifuge, use a damp cloth and a mild, noncorrosive detergent (pH <8). 
After cleaning, ensure all parts are dried thoroughly before attempting 
to operate the unit. Do not immerse the microcentrifuge in liquid or pour 
liquids over it.

Questions and Service

Should you have a question about the microcentrifuge or required service 
for the unit, please use the contact numbers listed. Do not send a unit for 
service without first calling to obtain a repair authorization (RA) number 
and a decontamination form. Should the microcentrifuge require service, 
be sure to decontaminate it and enclose the decontamination form. The 
unit should be properly packed to avoid damage. Any damage resulting 
from improper packaging shall be the responsibility of the user.

Operation

Before operating the microcentrifuge, be sure that the power switch on the 
back of the unit is in the “on” position. To begin a run, simply close the lid 
of the microcentrifuge. No other controls are required.

Fast Stop: 

Press down and release the tab on the front of the lid. This will 

release the lid lock, allowing the lid to open and the rotor to come to a 
fast braked stop.

Gradual Stop: 

Put the power switch in the “off” position, this will cut 

power to the motor and the rotor will come to a gradual stop.

Caution: 

Do not attempt to open the lid or remove samples until the unit 

has come to a complete stop. Once the lid has fully opened and the rotor 
has stopped, samples may be removed from the rotor.

Safe operation of the microcentrifuge requires that the rotor be loaded in 
a balanced fashion. Failure to load the rotor properly presents a hazardous 
condition and may damage the microcentrifuge. Individual tubes, strip tubes, 
and/or adapters must always be loaded symmetrically to ensure proper 
balance. Never run the microcentrifuge with only one individual tube or 
strip tube in place.

Equipment Maintenance

The microcentrifuge should be cleaned periodically. Ensure that the unit is 
not plugged in. Use a damp cloth and a mild, noncorrosive detergent (pH <8).  
Do not immerse the microcentrifuge in liquid or pour liquids over it. Excessive 
amounts of liquid should be avoided. Liquid should not come in contact 
with the motor. After cleaning, ensure all parts are dried thoroughly before 
attempting to operate the unit.

Rotors

The microcentrifuge is supplied with two interchangeable quick release 
rotors. No tools are required to exchange the rotors or attach them to 
the motor shaft. The rotors can be easily exchanged with one hand by 
way of the quick release system. Removal of the rotors is done by placing 
your thumb on top of the motor shaft and lifting up with two fingers 
underneath the rotor. Place the other rotor into position on the motor shaft 
and snap in.

  

8 place tube rotor 

4 place strip rotor