10
SGH Series
230V, 50Hz
REVISION # 0001
DATE: 07/20/2020
WIRING INSTRUCTIONS
Disconnect power at the fuse box before proceeding with any wiring.
1. Do not install any wiring or attempt to run this operator without checking the wiring diagram located
on the inside of the control box cover.
2. Do not turn on power until you have finished making all power and control wiring connections.
3. Do not run power and control wiring in the same conduit.
4. Any wire connected to the control panel must be protected by conduit or other means to ensure the
safety and permanency of the wiring.
5. Use copper wire inside the control panel.
6. A separate circuit of adequate capacity is needed for the operator.
7. The operator must be properly grounded. The ground screw, painted green, is located inside the
control panel.
8. For an operator, system, or external device requiring field installed wiring between a Class 2 output of
an operator and an external device, the type of wiring shall be R/C (AVLV2/8), AWM, min. 22 AWG,
rated 60°C, with VW-1/FT2.
Failure to properly ground the operator could result in electric shock and
serious injury or death.
To avoid damage to door and operator, make all door locks inoperative.
Secure lock(s) in the unlocked position, or install electrical interlocks to
prevent operation with the lock engaged.
WARNING
WARNING
WARNING