background image

 

MAX 171 ATX

 

COD. 6928900000 

- PRIMA DI UTILIZZARE  LA MACCHINA E’ OBBLIGATORIO LEGGERE E COMPRENDERE IN 
TUTTE LE SUE PARTI  IL SEGUENTE MANUALE 
- YOU HAVE TO READ CAREFULLY ALL THIS MANUAL BEFORE USING WELDING MACHINE 

 

 

ISTRUZIONI PER L’USO E MANUTENZIONE 

INSTRUCTION FOR USE AND MAINTENANCE 

 

Summary of Contents for MAX 171 ATX

Page 1: ...IZZARE LA MACCHINA E OBBLIGATORIO LEGGERE E COMPRENDERE IN TUTTE LE SUE PARTI IL SEGUENTE MANUALE YOU HAVE TO READ CAREFULLY ALL THIS MANUAL BEFORE USING WELDING MACHINE ISTRUZIONI PER L USO E MANUTENZIONE INSTRUCTION FOR USE AND MAINTENANCE ...

Page 2: ...zate and also declares that the following harmonised standards have been applied QUALSIASI MODIFICA ALLA MACCHINA SENZA L AUTORIZZAZIONE DI STEL s r l RENDERÀ NULLA QUESTA DICHIARAZIONE ANY MODIFICATION OF THE MACHINE WITHOUT THE AUTHORISATION OF STEL s r l RENDERS THIS DECLARATION VOID MAX 171 ATX Code 600216000L S N 73 23 CEE 89 336 CEE 92 31 CEE 93 68 CEE 2006 95 EEC 2004 108 CEE EN 60974 10 EN...

Page 3: ......

Page 4: ...39525 central 39 0444 639682 comm FAX 39 0444 639641 E mail info stelgroup it http www stelgroup it IL PRESENTE MANUALE E PARTE INTEGRANTE DELLA MACCHINA E DEVE ESSERE CONSERVATO PER FUTURI RIFERIMENTI THIS MANUAL IS AN INTEGRAL PART OF THE WELDING MACHINE AND MUST BE KEPT FOR FUTURE ...

Page 5: ... COD 6928900000 Gentile Cliente grazie per la fiducia accordataci Le macchina MAX 171 ATX e costruita secondo la filosofia STEL che associa qualità ed affi dabilità nella conformità delle normative sulla sicurezza Grazie alla tecnologia con cui e costruita MAX 171 ATX risulta avere delle caratteristiche di namiche ottimizzate per delle massime prestazioni in saldatura PRESENTAZIONE ITALIANO ...

Page 6: ...OSTERIORE 5 0 PREPARAZIONE DEL GENERATORE 5 1 DESCRIZIONE DELLE FUNZIONI DI SALDATURA 5 2 SALDATURA AD ELETTRODO ARC 5 3 SALDATURA AD ELETTRODO CELLULOSICO CEL 5 4 SALDATURA TIG LIFT 5 5 V R D 5 6 TARGA DATI 6 0 SALDATURA AD ELETTRODO 6 1 PROCEDIMENTO E DATI TECNICI DELLA SALDATURA AD ELETTRODO 6 2 FASI DELLA SALDATURA AD ELETTRODO 6 3 CARATTERISTICHE DI ALCUNI ELETTRODI DI USO COMUNE 6 4 DISTANZE...

Page 7: ...un generatore di corrente non saldare contenitori sotto pressione non saldare in ambienti contenenti polveri o vapori esplosivi LE RADIAZIONI GENERATE DALL ARCO Dl SALDATURA POSSONO DANNEG GIARE GLI OCCHI E PROVOCARE BRUCIATURE ALLA PELLE Proteggere gli occhi ed il corpo adeguatamente È indispensabile per i portatori di lenti a contatto proteggersi con apposite lenti e maschere IL RUMORE PUÒ DANNE...

Page 8: ... la macchina in atmosfere che contengano concentrazioni elevate di pol veri gas infiammabili o vapori combustibili PREVENZIONE CONTRO SHOCK ELETTRICI Prendere le seguenti precauzioni quando si opera con un generatore di corrente tenere puliti se stessi ed i propri vestiti non essere a contatto con parti umide e bagnate quando si opera con il generatore mantenere un isolamento adeguato contro gli s...

Page 9: ...arco indipendentemente dalla variazione del carico e dell impedenza dei cavi di saldatura I comandi sul pannello frontale consentono una facile programmazione delle sequenze di saldatura in funzione delle esigenze operative La tecnologia inverter usata ha permesso di ottenere generatori con peso e dimensioni estremamente contenuti ridotto consumo energetico eccellente risposta dinamica fattore di ...

Page 10: ...isolamento Raffreddamento Temperatura di lavoro Lunghezza Larghezza Altezza Peso mm IP C mm mm mm kg 35 54 H AF 40 400 170 300 15 GENERATORE PARAMETRI IN INGRESSO Tensione di alimentazione nominale Scostamento massimo Fasi Frequenza Corrente nominale MAX Corrente nominale DC 60 Corrente nominale DC 100 Potenza nominale MAX Potenza nominale DC 60 Potenza nominale DC 100 Fattore di potenza MAX Fusib...

Page 11: ... è un danno evidente vedere la sezione RECLAMI Par 3 2 nel manuale di istru zioni Prima di operare con il generatore leggere attentamente questo manuale di istruzione 3 2 3 2 3 2 3 2 RECLAMI RECLAMI RECLAMI RECLAMI Reclami per danneggiamento durante il trasporto Se la Vs apparecchiatura viene danneggia ta durante la spedizione dovete inoltrare un reclamo al Vs spedizioniere Reclami per merce difet...

Page 12: ...OD 6928900000 3 3 3 3 3 3 3 3 AVVERTENZA POSIZIONAMENTO PRECARIO AVVERTENZA POSIZIONAMENTO PRECARIO AVVERTENZA POSIZIONAMENTO PRECARIO AVVERTENZA POSIZIONAMENTO PRECARIO Se il generatore cade può causare infortuni Non mettere in funzione o spostare il generatore nel caso si trovi in posizione precaria Non posizionare il generatore su piani inclinati superiori a 10 DESCRIZIONE TECNICA ITALIANO ...

Page 13: ...inima 195V tensione massima 265V COLLEGAMENTO Prima di effettuare connessioni elettriche tra il generatore di corrente e l interruttore di linea accertarsi che quest ultimo sia aperto Il quadro di distribuzione deve essere conforme alle normative vigenti nel paese di utilizzo L impianto di rete deve essere di tipo industriale Il cavo multipolare è provvisto di una spina tipo CEE 3P T a norme Assic...

Page 14: ...nsabile predisporre una buona messa a terra tramite il conduttore giallo verde del cavo di alimentazione onde evitare scariche dovute a contatti accidentali con oggetti messi a terra Lo chassis che è conduttivo è connesso elettricamente con il conduttore di terra non col legare correttamente a terra l apparecchiatura può provocare shock elettrici pericolosi per l utente 3 6 3 6 3 6 3 6 SCHEMA COLL...

Page 15: ... ATX ATX ATX ATX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Led segnalazione allarme termico Led segnalazione abilitazione saldatura Led segnalazione macchina sotto tensione Led segnalazione modalità saldatura elettrodo Led segnalazione modalità saldatura elettrodo cellulosico Led segnalazione modalità saldatura Tig Lift Pulsante selezione modalità di saldatura menù regolazione A F Encoder regolazione corre...

Page 16: ... 39 444 639682 comm FAX 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 1 2 Cavo di alimentazione Fusibile 4 2 4 2 4 2 4 2 VISTA VISTA VISTA VISTA PANNELLO PANNELLO PANNELLO PANNELLO POSTERIORE POSTERIORE POSTERIORE POSTERIORE DESCRIZIONE TECNICA ITALIANO 1 2 ...

Page 17: ...lizzata sul display rif 14 cap 4 1 La corrente può essere regolata da 4 a 150A 4 La funzione Hot Start è già regolata automaticamente per avere una saldatura ottimale 5 Regolazione funzione Arc Force Premendo per 3 secondi il pulsante MODE rif 7 cap 4 1 si accede alla funzione ARC FORCE Sul display compare lampeggiando la scritta A F e poi il valore che può essere variato ruotan do l encoder da 0 ...

Page 18: ...ione rampa di discesa Slope Down Premendo il pulsante MODE rif 14 pag 8 per 3 secondi si seleziona il tempo di rampa di discesa Il display rif 9 pag 8 comincerà a lampeg giare mostrando prima la scritta SLo e indicando poi il valore selezionabile con l encoder rif 8 cap 4 1 La rampa di discesa può essere esclusa portando al minimo la regolazione dell encoder compare la scritta 0 0 sul display La r...

Page 19: ...e a rischio accresciuto di scossa elettrica Simbolo della corrente di saldatura Tensione assegnata a vuoto tensione media Gamma della corrente di saldatura Valori del ciclo di intermittenza su 10 minuti Valori della corrente assegnata di saldatura Valori della tensione convenzionale a carico Simbolo per l alimentazione numero fasi e frequenza Tensione assegnata di alimentazione Massima corrente di...

Page 20: ...sostanze minerali ed organiche miscelate fra loro le cui funzioni sono Protezione gassosa Una parte del rivestimento volatilizzata alla temperatura dell arco allon tana l aria dalla zona di saldatura creando una colonna di gas ionizzato che protegge il metallo fuso Apporto di elementi leganti e scorificanti Una parte del rivestimento fonde e apporta nel ba gno di fusione degli elementi che si comb...

Page 21: ...reparazione dei lembi da saldare La preparazione dei lembi varia a seconda dello spessore del materiale da saldare della po sizione di saldatura dal tipo di giunto e dalle esigenze di realizzazione Comunque è sempre consigliabile lavorare su parti pulite non ossidate o che non presentino ruggine o altre so stanze che potrebbero danneggiare la saldatura I lembi possono venire preparati con delle ci...

Page 22: ...ostruttore stesso Accensione dell arco L arco elettrico si accende sfregando la punta dell elettrodo sul pezzo da saldare ritraendo rapidamente l elettrodo fino al mantenimento dell arco Un movimento troppo lento può provocare l incoraggio dell elettrodo al pezzo in questo caso con uno strappo laterale si libera l elettrodo mentre un movimento troppo veloce può provo care lo spegnimento dell arco ...

Page 23: ...l elettrodo viene eseguito tramite oscillazioni e fermate ai lati del cordone in modo da evi tare l accumulo di materiale d apporto al centro della saldatura Asportazione della scoria Per gli elettrodi rivestiti si rende necessaria l asportazione della scoria dopo ogni passata L asportazione si esegue tramite un piccolo martello oppure per scorie friabili con una spaz zola metallica Per una corret...

Page 24: ...pen teria per saldatura di serbatoi a pressione dove vengono utilizzati acciai avente un carico di rottura di 360 490 N mm Ottimo per impiego di saldature di la miere sottili e di lavori di puntatura Questo elettrodo è caratterizzato da bassis simo assorbimento all umidità atmosferica CARATTERISTICHE MECCANICHE MEDIE Limite di snervamento 460 N mm Carico di rottura 550 N mm Allungamento A5D 24 Res...

Page 25: ...ella saldatura Es controlli US RX ecc Questo è un elettrodo caratterizzato da rivestimento a bassissimo assorbimento di umidità atmosferica CARATTERISTICHE MECCANICHE MEDIE Limite di snervamento 450 N mm Carico di rottura 520 N mm Allungamento A5D 28 Resilienza KV J C 200 20 180 0 160 20 90 40 Dimensioni Kg di dep Per ogni Kg di elet trodi N di elet trodi per Kg di de posito Kg deposi tati per ora...

Page 26: ... essere utilizzato anche per la saldatura di acciaio inox stabilizzato Suggerito quando l estetica del cordone di saldatura è di primaria importanza CARATTERISTICHE MECCANICHE MEDIE Limite di snervamento 435 N mm Carico di rottura 580 N mm Allungamento A5D 38 Resilienza KV J C 65 20 38 120 Dimensioni Kg di dep Per ogni Kg di elet trodi N di elet trodi per Kg di de posito Kg deposi tati per ora di ...

Page 27: ...a in tutte le posizioni di tubazioni in acciaio tipo API 5LX X42 X 46 X52 ecc Di facile impiego scorrevole e penetrante Particolarmente adatto per la saldatura in opera in verticale discen dente e sopratesta Ottime qualità radiografiche CARATTERISTICHE MECCANICHE MEDIE Limite di snervamento 380 N mm Carico di rottura 460 N mm Allungamento A5D 24 Resilienza KV J C 48 0 27 30 Dimensioni Intensità di...

Page 28: ...LETICA DI SICUREZZA SEGNALETICA DI SICUREZZA SEGNALETICA DI SICUREZZA PER SALDATRICI CONFORME ALLA DIRETTIVA 92 58 CEE E ALLE NORME UNI 7543 1 3 ATTENZIONE ATTENTION BEWARE ACHTUNG ATENCION ITALIANO 6 4 6 4 6 4 6 4 DISTANZE POSTERIORI E LATERALI DA MANTENERE DISTANZE POSTERIORI E LATERALI DA MANTENERE DISTANZE POSTERIORI E LATERALI DA MANTENERE DISTANZE POSTERIORI E LATERALI DA MANTENERE DURANTE L...

Page 29: ...TERMITTENZA INTERMITTENZA DC DC DC DC E E E E SOVRATEMPERATURA SOVRATEMPERATURA SOVRATEMPERATURA SOVRATEMPERATURA Il ciclo di intermittenza è la percentuale su 10 minuti che l operatore deve rispettare per non en trare in sovratemperatura Se la macchina entra in sovratemperatura il LED giallo rif 1 cap 4 1 si accende E necessario quindi attendere circa 10 minuti per riprendere a saldare Occorre ri...

Page 30: ...group it MAX 171 ATX COD 6928900000 6 7 6 7 6 7 6 7 CURVE CURVE CURVE CURVE TENSIONE TENSIONE TENSIONE TENSIONE CORRENTE CORRENTE CORRENTE CORRENTE Static characteristic MAX 171 ATX 230V 1f 0 5 10 15 20 25 30 35 40 45 50 55 60 0 20 40 60 80 100 120 140 160 180 Current A Voltage V MAX 171 ATX Ioutmax160A MAX 171 ATX Ioutmin4A Max 171 ATX Iout 100A AF30 ITALIANO FIGURE 150A ...

Page 31: ...ne dei pez zi da saldare SPRUZZI ELEVATI Inclinazione elettrodo eccessiva Effettuare le opportune correzioni DIFETTI Dl PROFILI Parametri saldatura non corretti Velocità passata non legata alle esigenze dei parametri operativi Inclinazione dell elettrodo non costante durante la saldatura Rispettare i principi basilari e generali di saldatura INSTABILITÀ D ARCO Corrente insufficiente Controllare lo...

Page 32: ...traccia di polvere dalle parti interne del generatore mediante getto d aria com pressa con pressione non superiore a 3 Kg cm2 0 3 M Pa Controllare tutte le connessioni elettriche assicurandosi che viti e dadi siano ben serrati Non esitare nel sostituire i componenti deteriorati Rimontare la copertura ripristinando obbligatoriamente la siliconatura sulla guarnizione Tipo silicone SISTA SILICON 5 UN...

Page 33: ...UZIONE FILTRI POLVERI SOSTITUZIONE FILTRI POLVERI SOSTITUZIONE FILTRI POLVERI FILTR0 POLVERE ANTERIORE FILTR0 POLVERE ANTERIORE FILTR0 POLVERE ANTERIORE FILTR0 POLVERE ANTERIORE 1 Svitare le 2 viti di fissaggio della griglia di supporto filtro polve ri 2 Togliere l intero blocco formato dal filtro e dalla griglia di sup porto 3 Sostituire il filtro cod 6610230000 lasciando in posizione la re tina ...

Page 34: ...MANUTENZIONE ITALIANO FILTR0 POLVERE POSTERIORE FILTR0 POLVERE POSTERIORE FILTR0 POLVERE POSTERIORE FILTR0 POLVERE POSTERIORE 1 Svitare le 2 viti di fissaggio della griglia di supporto filtro polveri 2 Togliere l intero blocco formato dal filtro e dalla griglia di supporto 3 Sostituire il filtro cod 6610230000 lasciando in posizione la retina 4 Fissare nuovamente la griglia supporto filtri mediant...

Page 35: ...ATERALE FILTRO POLVERE LATERALE 1 Svitare le 2 viti di fissaggio della griglia anteriore di supporto filtro polveri 2 Sostituire il filtro cod 6610230000 lasciando in posizione la retina importante il filtro polveri dev essere sotto la retina 3 Fissare nuovamente la griglia mediante le 2 viti N B SI RACCOMANDA DI USARE SEMPRE FILTRI POLVERE ORIGINALI PER UN CORRETTO FUNZIO NAMENTO DEL GENERATORE E...

Page 36: ...e alla prescrizioni del le normative vigenti Procedere alla differenziazione delle parti che costituiscono la macchina secondo i diver si tipi di materiale di costruzione Plastica rame ferro ecc MANUTENZIONE ITALIANO È OBBLIGATORIO TOGLIERE LA SPINA DI CONNESSIONE DALLA PRESA DI ALIMENTAZIONE ELETTRICA PRIMA DI ESEGUIRE LO SMONTAGGIO DEI COMPONENTI DELLA SALDATRICE I CONDENSATORI ELETTROLITICI INS...

Page 37: ...group it MAX 171 ATX COD 6928900000 PRESENTATION ENGLISH Dear Customer Thank you for choosing our product The MAX 171 ATX machine is built according to the STEL philosophy which combines quality and reliability with the respect of safety regulations Thanks to the technology with which MAX 171 ATX built it has optimum dynamic characteristics and maximum welding performances ...

Page 38: ...X GENERATOR FRONT PANEL 4 2 VIEW OF REAR PANEL 5 0 PREPARING THE GENERATOR 5 1 DESCRIPTION OF THE WELDING FUNCTIONS 5 2 ARC ELECTRODE WELDING 5 3 CELLULOSIC ELECTRODE WELDING 5 4 TIG WELDING 5 5 V R D 5 6 DATA PLATE 6 0 ELECTRODE WELDING 6 1 PROCEDURES AND TECHNICAL DATA FOR ELECTRODE WELDING 6 2 ELECTRODE WELDING PHASES MMA 6 3 CHARACTERISTICS OF SOME ELECTRODES OF COMMON USE 6 4 REAR AND SIDE DI...

Page 39: ... IF WELDED When working with a current generator do not weld pressurised containers do not weld in environments containing explosive powders or vapours THE RADIATIONS GENERATED BY THE WELDING ARC CAN DAMAGE THE EYES AND CAUSE BURNING OF THE SKIN Provide suitable protection for the eyes and body It is indispensable for contact lens wearers to protect themselves with suitable lenses and masks NOISE ...

Page 40: ...fore using the machine do not use the machine in atmospheres containing high concentrations of powders inflammable gases or combustible vapours PREVENTION OF ELECTRIC SHOCK Take the following precautions when working with a current generator keep yourself and your clothes clean do not be in contact with damp or wet parts when working with the generator maintain suitable insulation against electric...

Page 41: ...imises the transfer of the arc irrespective of the load variation and of the impedance of the welding cables The controls on the front panel allow easy programming of the welding sequences depending on the operating requirements The inverter technology used has allowed the following to be obtained generators with extremely low weight and compact dimensions reduced energy consumption excellent dyna...

Page 42: ...TX Welding cables Degree of protection Insulation class Cooling Working temperature Length Width Height Weight mm IP C mm mm mm kg 35 54 H AF 40 400 170 300 15 GENERATOR INPUT PARAMETERS Rated supply voltage Maximum drift Phases Frequency Rated current MAX Rated current DC 60 Rated current DC 100 Rated power MAX Rated power DC 60 Rated power DC 100 Power factor MAX Protection fuses Power cable OUT...

Page 43: ...e contains MAX 171 ATX N 1 current generator for welding 600215000L N 1 instructions manual 6918900000 N 1 package 67XXX00000 Check that all the material listed above is included in the package Notify your distributor if anything is missing Ensure that the generator has not been damaged during transport If there is any visible damage see the COMPLAINTS section Par 3 2 for instructions Read this in...

Page 44: ...28900000 3 3 3 3 3 3 3 3 INSTRUCTION FOR INSECURE POSITIONING INSTRUCTION FOR INSECURE POSITIONING INSTRUCTION FOR INSECURE POSITIONING INSTRUCTION FOR INSECURE POSITIONING Failure to properly secure the machine con cause personal injury If machine is in an insicure position do not attempt to switch on Do not put the power source on an unlevel surface greater then a 10 TECHNICAL DESCRIPTION ENGLIS...

Page 45: ... SUPPLY PANELS SUPPLY PANELS SUPPLY PANELS SUPPLY PANELS ATTENTION The security protection for the Red Emergency button ref 12 cap 4 1 on the front panel is active only if the 4th secuirty core of the supply cable is correctly connected The plug and the socket must be of the type as specified in the diagram at Cap 10 3 MODEL VOLTAGE PHASES DELAYED FUSE MAX 171 ATX 230V 1 PHASES 16 A 3 4 3 4 3 4 3 ...

Page 46: ...arthing by means of the yellow green lead in the power cable in order to avoid discharges due to accidental contacts with earthed objects The chassis which is conductive is electrically connected with the earth lead if the equipment is not suitably connected to earth it may cause electric shocks which are dangerous for the user 3 6 3 6 3 6 3 6 ELECTRIC DIAGRAM OF THE EARTHING CONNECTION FOR ELECTR...

Page 47: ...RONT PANEL CONTROLS ON THE MAX 171 ATX GENERATOR FRONT PANEL TECHNICAL DESCRIPTION ENGLISH CONNECTION TO SUPPLY MAINS GENERAL WELDING PROCESS EXCESS TEMPERATURE ALARM ARC FORCE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Thermal alarm warning led Welding enabled warning led Machine live warning led Electrode mode warning led Electrode cellulosic warning led Tig lift mode warn...

Page 48: ...9 444 639525 central 39 444 639682 comm FAX 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 4 2 4 2 4 2 4 2 VIEW OF REAR PANEL VIEW OF REAR PANEL VIEW OF REAR PANEL VIEW OF REAR PANEL 1 2 Power cable Fuse TECHNICAL DESCRIPTION ENGLISH 1 2 ...

Page 49: ... shown on the display ref 14 cap 4 1 The current may be regulated from 4 to 150A 4 The Hot Start function is already automatically regulated to have optimum welding 5 Regulating the Arc Force function Press the MODE button rif 7 cap 4 1 for 3 seconds for regulate the ARC FORCE The blinking letters A F appear on the display and then the value which can be varied by turning the encoder from 0 to 500...

Page 50: ...ap 4 1 5 Regulating Slope Down Pressing the MODE button ref 7 cap 4 1 for 3 seconds selects the slope down time The display ref 14 pacap 4 1 will start to blink indicating first the letters SLo and then the value that can be selected with the encoder ref 8 cap 4 1 slope down may be excluded by reducing the encoder regulation to a minimum the letters 0 0 appear on the display The slope regulation v...

Page 51: ...itable for working in an environment with a high risk of electric shock Symbol of the welding current Assigned no load voltage mean voltage Range of the welding current Values of the intermittence cycle in 10 minutes Values of the assigned welding current Values of the conventional loaded voltage Power supply symbol number of phases and frequency Assigned power supply voltage Maximum power supply ...

Page 52: ...lding zone creating a column of ionised gas which protects the molten metal Supply of bonding and scarifying elements A part of the coating melts and supplies elements to the weld pool which combine with the base material forming slag It may be said that the manner of melting and the characteristics of the deposit of each electrode derive from the type of coating and from the core material The pri...

Page 53: ...e weld is needed Table for preparing U shaped edges b Choosing the electrode The choice of the electrode diameter depends on the thickness of the material the type of joint and the welding position When welds in position are needed the pool tends to slip due to gravity so it is recommended to use electrodes with a small diameter making a series of passes For electrodes with a large diameter high w...

Page 54: ...is case the electrode may be freed by pulling it to one side on the other hand if the movement is too fast it may extinguish the arc Making the weld There are many techniques for making the joints and they vary according to the operator s requirements Two classical methods will be studied as an example s mm a mm d mm α 0 3 3 6 3 12 0 0 0 1 5 0 s 2 MAX 0 2 0 0 60 Electrode diameter mm Welding curre...

Page 55: ...e the movement of the electrode is performed by swinging it and stopping at the sides of the seam so as to avoid the accumulation of weld material in the centre of the weld Removing slag For coated electrodes it is necessary to remove the slag after each pass The slag is removed with a small hammer or in the case of brittle slag with a wire brush To make the different types of joint correctly in t...

Page 56: ...average car pentry for welding tanks in pressure where they uses steels having a yield strength of 360 490 N mm Optimal for employment of weldings of thin plates and spot welding jobs This electrode is characterized by lowest absorption to the atmospheric humidity MEDIUM MECHANICAL CHARACTERISTICS Yield strength 460 N mm Tensile strength 550 N mm Elongation A5D 24 Resilience CHARPY KV J C 65 20 40...

Page 57: ...rom covering to lowest atmospheric humidity absorption MEDIUM MECHANICAL CHARACTERISTICS Yield strength 450 N mm Tensile strength 520 N mm Elongation A5D 28 Resilience CHARPY KV J C 200 20 180 0 160 20 90 40 Dimensions Kg of de position for every Kg of e lectrodes N of elec trodes for Kg of de position Kg depo sits for an hour of i gnited arc Time of fusion sec Intensity of cur rent advised Amp N ...

Page 58: ...e used also for the stabilized stainless steel welding Suggested when the esthetics of the welding is primary importance MEDIUM MECHANICAL CHARACTERISTICS Yield strength 435 N mm Tensile strength 580 N mm Elongation A5D 38 Resilience CHARPY KV J C 65 20 38 120 Dimensions Kg of de position for every Kg of e lectrodes N of elec trodes for Kg of de position Kg depo sits for an hour of i gnited arc Ti...

Page 59: ... API 5LX X42 X 46 X52 ecc Easy employment flowing and pe netrating Light slag and good wash in permit exellent control of the arc Particu larly adapted for the welding in work in vertical descendant and overhead Opti mal X ray qualities MEDIUM MECHANICAL CHARACTERISTICS Yield strength 380 N mm Tensile strength 460 N mm Elongation A5D 24 Resilience CHARPY KV J C 48 0 27 30 Dimensions Intensity of c...

Page 60: ...SIGNS SAFETY SIGNS SAFETY SIGNS SAFETY SIGNS ATTENZIONE ATTENTION BEWARE ACHTUNG ATENCION SAFETY SIGNS FOR WELDING MACHINES IN COMPLIANCE WITH DIRECTIVE 92 58 EEC AND WITH STANDARDS UNI 7543 1 3 6 4 6 4 6 4 6 4 REAR AND SIDE DISTANCES TO BE MAINTAINED DURING REAR AND SIDE DISTANCES TO BE MAINTAINED DURING REAR AND SIDE DISTANCES TO BE MAINTAINED DURING REAR AND SIDE DISTANCES TO BE MAINTAINED DURI...

Page 61: ...YCLE LE LE LE DC AND EXCESS TEMPERA DC AND EXCESS TEMPERA DC AND EXCESS TEMPERA DC AND EXCESS TEMPERATURE TURE TURE TURE The intermittence cycle is the percentage of use of the welding machine in 10 minutes which the operator must respect so as to avoid excess temperature If the machine goes into excess temperature the yellow led ref 1 cap 4 1 lights up It is therefore necessary to wait about 10 m...

Page 62: ...stelgroup it MAX 171 ATX COD 6928900000 6 7 6 7 6 7 6 7 CORRENT VOLTAGE CORRENT VOLTAGE CORRENT VOLTAGE CORRENT VOLTAGE CURVE CURVE CURVE CURVE Static characteristic MAX 171 ATX 230V 1f 0 5 10 15 20 25 30 35 40 45 50 55 60 0 20 40 60 80 100 120 140 160 180 Current A Voltage V MAX 171 ATX Ioutmax160A MAX 171 ATX Ioutmin4A Max 171 ATX Iout 100A AF30 ENGLISH FIGURES 150A ...

Page 63: ... movement Regulate the operative parameters and improve preparation of the parts to be welded HIGH SPLASHING Excessive electrode inclination Make the necessary corrections PROFILE DEFECTS Incorrect welding parameters Passing speed not linked with the needs of the operative parameters Electrode inclination not constant during welding Respect the basic and general welding principles ARC INSTABILITY ...

Page 64: ...emove the cover Remove every trace of dust from the internal parts of the generator using a jet of compressed air with pressure not higher than 3 Kg cm2 0 3 M Pa Check all the electrical connections ensuring that screws and nuts are firmly secured Do not hesitate to replace worn components It is obligatory to apply silicone on the Gasket when refitting the cover Silicon type SISTA SILICON 5 UNIVER...

Page 65: ...up it MAX 171 ATX COD 6928900000 ENGLISH REPLACE DUST FILTERS REPLACE DUST FILTERS REPLACE DUST FILTERS REPLACE DUST FILTERS FRONT DUST FILTER FRONT DUST FILTER FRONT DUST FILTER FRONT DUST FILTER 1 Unscrew the 2 retaining screws of the dust filter support 2 Remove the filter and the support grid 3 Replace the filter cod 610230000 4 Fix the grid with the 2 screws MAINTENANCE ...

Page 66: ...41 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 ENGLISH MAINTENANCE REAR DUST FILTER REAR DUST FILTER REAR DUST FILTER REAR DUST FILTER 1 Unscrew the 2 retaining screws of the dust filter support 2 Remove the filter and the support grid 3 Replace the filter cod 610230000 4 Fix the grid with the 2 screws ...

Page 67: ...DE DUST FILTER SIDE DUST FILTER 1 Unscrew the 2 retaining screws of the side dust filter support 2 Replace the filter cod 6610230000 from the support grid and leave the net in its position important the side dust filter under the mesh 3 Fix the grid with the 2 screws P N TO GUARANTEE THE PERFORMANCES OF THE WEL DING POWER SOURCE TOGEHTER WITH ITS DEGREE OF PROTECTION WE RECOMMEND TO USE ALWAYS ORI...

Page 68: ...IC CONDENSERS INSTALLED INSIDE THE MACHINE REMAIN LIVE EVEN AFTER THE CONNECTING PLUG HAS BEEN REMOVED FROM THE POWER SOCKET IT IS OBLIGATORY TO WAIT AT LEAST 5 MINUTES BEFORE REMOVING THE MACHINE HOOD AND ACCESSING THE INSIDE 8 0 8 0 8 0 8 0 GENERAL WARNINGS FOR DISPOSAL GENERAL WARNINGS FOR DISPOSAL GENERAL WARNINGS FOR DISPOSAL GENERAL WARNINGS FOR DISPOSAL When the machine is to be scrapped yo...

Page 69: ...w stelgroup it MAX 171 ATX COD 6928900000 9 0 9 0 9 0 9 0 LIST OF COMPONENTS AND EXPLODED VIEWS LIST OF COMPONENTS AND EXPLODED VIEWS LIST OF COMPONENTS AND EXPLODED VIEWS LIST OF COMPONENTS AND EXPLODED VIEWS 9 1 9 1 9 1 9 1 LIST LIST LIST LIST OF OF OF OF COMPONENTS MAX 171 ATX COMPONENTS MAX 171 ATX COMPONENTS MAX 171 ATX COMPONENTS MAX 171 ATX SPARE PARTS ENGLISH ...

Page 70: ...RONT PANEL XL OUT SHEATH ENCODER FRONT PANEL KNOB d 22 SOCKET GRID STOP BUTTON EMERGENCY BUTTON START BUTTON INSTRUMENT STICKER BUTTON DISSIPATOR SUPPORT RESISTOR RESISTOR DIODE IP PROTECTION Cu CONNECTION Cu CONNECTION PCB SUPPORT PCB POWER INVERTER COVER HANDLE SHEATH CONNECTOR XL PFC AUXILIARY TRASFORMER SWITCH SUPPORT POWER SWITCH TERMINAL BLOCK SWITCH CABLE COMPRESSION GLAND INPUT SUPPLY CABL...

Page 71: ...CENZA ITALY TEL 39 444 639525 central 39 444 639682 comm FAX 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 ENGLISH SPARE PARTS DESCRIPTION MAX 171 ATX 46 47 48 REAR PANEL FAN SUPPORT FAN MOTOR 620414RC 6204080U 61133100 ...

Page 72: ...X 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 10 0 10 0 10 0 10 0 WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM 10 1 10 1 10 1 10 1 WIRING DIAGRAM MAX 171 ATX WIRING DIAGRAM MAX 171 ATX WIRING DIAGRAM MAX 171 ATX WIRING DIAGRAM MAX 171 ATX ELECTRICAL PART ENGLISH ...

Page 73: ...X 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 10 2 10 2 10 2 10 2 WIRING DIAGRAM OF CO WIRING DIAGRAM OF CO WIRING DIAGRAM OF CO WIRING DIAGRAM OF CONNECTION PLUG NNECTION PLUG NNECTION PLUG NNECTION PLUG MAX 171 ATX MAX 171 ATX MAX 171 ATX MAX 171 ATX ELECTRICAL PART ENGLISH ...

Page 74: ...ro VICENZA ITALY TEL 39 444 639525 central 39 444 639682 comm FAX 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 ELECTRICAL PART ENGLISH 10 3 10 3 10 3 10 3 WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM ...

Page 75: ...L s r l Via del Progresso n 59 36020 Loc Castegnero VICENZA ITALY TEL 39 444 639525 central 39 444 639682 comm FAX 39 444 639641 E mail stel stelgroup it http www stelgroup it MAX 171 ATX COD 6928900000 NOTES ...

Reviews: