10
Dual SGH500E Series
REVISION # 0001
DATE: 11/04/2020
CONTROL WIRING
If the door is not visible from the control station, or if any device other than
the control station is used to activate the door, an entrapment protection
device must be installed on the door. Failure to install an entrapment
protection device may result in serious injury or death to person(s) trapped
beneath the door.
1. Complete limit switch adjustments before making any sensing edge/non-contact device wiring
connections to the operator.
Sensing
Edge
6" max. above floor
6"
Photo Eye
Entrapment Device Options:
Sensing Module
Device Manufacturer
Model
ELR
2-wire resistive sensing
edge
Miller Edge Inc.
*
End of Line resistor type
edge must have model
number with Suffix T2.
ME110*, ME111*, ME120*, ME123*, ME112*,
ME113*, ME116*, ME117*
MT21*, MU21*, MT22*, MU22*, MC22*, MU33*,
MC271*, CPT223*
MEL-TXYY, MEL-RXYY
RB-G-K10
ASO
GE225, GE125, GE245, GE F45, GE F50, GE F56,
GE F65, GE F85, GE F115
IR
Monitored photo eye
FRABA Inc.
Optical Edge Sensors and Photo Eyes, Models
OPTOEDGE, OPTOEYE, OSE, OPE, OSE-P,
OSE-R, OSE-T, RAY-N
Reflective Photo Eye, Models Ray/RT -1004, -2004
Martec Access Products Inc.
1266
Miller Edge Inc.
IG2, MIRM
RB-D-K10
Note
:
Please refer to sensing device manufacturer for specific installation and maintenance requirements.
WARNING