Section 7 – Maintenance
32
Motor Operator Installation:
1. Unpack the motor operator from the shipping box and retrieve the
Operator Mounting Bracket
and
bolts provided in the kit.
2. There are several motor mounting configurations that can be formed with the supplied
components. Refer to the shop drawings and components supplied with the kit in order to identify
the specific style of mounting ordered for the unit. Some of the types of mounting are:
•
Horizontal Top of Coil
•
Horizontal Front of Coil
•
Tube Motor (factory installed)
3. Mount the operator mounting bracket to the operator using the supplied fasteners.
4. Mount the operator mounting
bracket
to the operator bracket according to the shop drawings
using the supplied fasteners.
5. Install controls and wire the operator. Refer to the wiring diagram provided with the operator for
proper connections and voltages. The controls should be installed in an area from which the
door/opening is clearly visible. This will allow an individual operating the unit to make a visual
inspection of the opening for any obstacles or other potential hazards before setting the door into
motion.
Note:
Do not attempt to set the upper and lower limits until the curtain is installed or released.
Attaching Additional Bracing (if required)
1. Attach a clip angle to the operator mounting bracket and the bracing angle to the clip angle.
Snug all bolts.
2. Mount the other supplied clip angle to the bracing angle and swing the bracing angle to the wall
or structural support.
3. Align the mounting face of the clip angle with the face of the wall, mark and drill a mounting hole
for the size of the supplied mounting fastener, and secure the clip angle to the wall with the
fastener.
4. Square the operator-mounting bracket, adjusting the bracing angle as necessary, and fully tighten
all the mounting bolts.
5. Lift the motor operator into position on the mounting bracket and align it with the appropriate hole
pattern.
6. Insert the fasteners included in the kit from the bracket side first into the mounting foot of the
operator and tighten the nuts with lock washers.
Note:
All mounting bolts are supplied with nuts and lock washers.