10
Automatic ignition with flame failure safety device
The appliance is fitted with a flame failure safety device on each
burner, which is designed to stop the flow of gas to the burner head in
the event of the flame going out.
To ignite a burner:
o
Press in the control knob of the burner that you wish to light and
turn it anti-clockwise to the maximum position.
o
If you keep the control knob depressed, the automatic ignition
for the burner will operate.
o
You should hold down the control knob for 15 seconds after the
flame on the burner has lit. If after 15s the burner has not lit,
stop operating the device and open the compartment door
and/or wait at least 1 min before attempting a further ignition of
the burner.
o
After this 15-second interval, to regulate the flame you should
continue turning the control knob anti-clockwise until the flame
is at a suitable level. The operating position MUST be at a
position between the maximum and minimum position.
o
To switch the burner off, turn the control knob fully clockwise to
the gas off position.
o
In case of power failure, the burners can be lit by carefully using
a match.