Viper Service Manual
Publication Number: 621260373SER
- 48 -
© 2008-2015, Cornelius Inc.
Sanitizing the Barrel
Sanitize the syrup system and barrel by performing the procedure shown in Table 40.
Table 39.
Step
Action
1.
Fill a clean 5-gallon pail with plain water.
2.
Connect a sanitizing fitting (p/n cc 28688) to the BIB connector. Put the connector in the bucket of water.
3.
Make sure the Product/BRIX valve is in the BRIX position.
4.
Hold a waste container under the brix tube to collect syrup from the syrup line and open the manual syrup
flow valve (see Figure 32.) to start filling the syrup line with plain water. Continue to hold the manual syrup
flow valve open until clean water starts coming out of the BRIX tube.
5.
Release the manual syrup flow valve and turn the Product/BRIX valve to the Product position.
6.
Open the manual water flow valve (see Figure 32.) to start filling the barrel with water. At the same time,
open the faceplate relief valve until water comes out.
7.
When the barrel is full, press the SPIN button on the Barrel Status menu, while highlighting the appropriate
barrel. This starts the scraper blade. Allow blade to operate for fifteen seconds.
8.
Turn barrel OFF by pressing the OFF button.
9.
Place a waste container under the barrel dispensing valve. Open the dispensing valve and dispense all
wash water from the barrel. When the pressure in the barrel drops, from the Barrel Maintenance menu,
press the PURGE button to re-pressurize the barrel with CO
2
. As the wash water level lowers in the barrel,
partially close the valve to avoid spurting.
10.
Perform rear barrel seal replacement. See “Barrel Motor Seal Replacement” on page 51.
11.
Perform inspection and replacement of scraper blades. See “Inspecting and Replacing Scraper Blades” on
page 44.
12.
Perform a leak test on the barrel. See “Motor Seal Leak Test” on page 53.
Table 40.
Step
Action
1.
Use a clean 5-gallon pall filled with a sanitizing solution and water at a temperature of 90º F to 110º F (32º C to
43º C). The sanitizing solution must have 200-ppm available chlorine.
2.
Connect a sanitizing fitting (p/n cc 28688) to the BIB connector. Put the connector in the bucket of sanitizing
solution.
3.
Make sure the
Product/BRIX valve is in the BRIX position.
4.
Hold waste container under the BRIX tube to collect flush water from the syrup line and open the manual syrup
flow valve to start filling the syrup line with sanitizing solution. Continue to hold the syrup flow valve open until
sanitizing solution starts coming out of the BRIX tube.
5. Turn
the
Product/BRIX valve in the Product
position.
6.
Manually override (open) the syrup flow valve to fill the barrel with sanitizing solution.
7.
Fill the barrel with sanitizing solution by opening the faceplate relief valve until sanitizing solution comes out of
the relief port.
8.
Hold a 16 oz. cup under the dispense valve. Hold the dispense valve fully open until the cup is full.