Syrup Flow
Control
Water Flow
Control
(Do Not Adjust)
Manual
Syrup Control
Valve
Manual
Water Control
Valve
Viper Service Manual
© 2008-2016, Cornelius Inc.
- 37 -
Publication Number: 621260373SER
Figure 32. Flow Controls
Motor Setup Menu
Motor setup is initially done at the factory and does not need to be changed unless a barrel motor or barrel
components are replaced, adjusted or removed and reinstalled.
This menu allows you to select different motor types for each barrel in the unit and run
the calibration procedure on that motor. This procedure correlates the actual viscosity of the barrel and its contents
with the electrical characteristics of the motor. These characteristics are stored by the control system and are
accessed at the time of calibration for each particular motor.
Because of the differences between motor characteristics from different motor suppliers, the Motor menu, shown in
Figure 33., is used to adjust the unit settings to match the motor type being installed. It provides the correct table of
electrical characteristics from imbedded settings located in non-volatile memory. Perform the procedure described
in Table 28 to change the motor type setting. Insure that the motor type matches the settings listed in Table 26
based on model.
MOTOR
SETUP
12:51P
MAR 04
#1 MOTOR TYPE 1
#2 MOTOR TYPE 2
BACK CAL - +
NOTE: If the Motor Type shown is “DEFAULT”, it indicates that the EEPROM is not installed or is
faulty.
Figure 33. Motor Setup Screen
Table 26.
Model
Motor Type
All 60 Hz
1
All 50 Hz
2