UCR 700 Series Continuous Flow Icemaker Installation/Service Manual
© 2001-2012, IMI Cornelius Inc.
- 8 -
Publication Number: 630460154
I
NITIAL
S
TART
UP
, C
HECKS
AND
A
DJUSTMENT
I
NSTRUCTIONS
NOTE: Do not start Icemaker before completing installation steps on pages 7 and 9.
Turn on water supply (if Icemaker is water cooled turn water on to condenser also) turn on main power switch
(located on top of electrical box), and make the following system checks:
NOTE: If Icemaker will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down the Icemaker. If water level drops below bottom of reservoir, the Icemaker
must shut down. Adjustment is made by moving magnet up or down.
Water Level
—If necessary adjust float by bending float arm up or down as needed, push float assembly down until
Icemaker stops running. Release float and Icemaker will restart. Keep water in reservoir at level line while the
Icemaker is in operation. (See Figure 3)
Low Water Safety Control
—Adjust magnet by bending magnet arm as needed to shut unit down if water level
drops below bottom of reservoir.
Bin Control
—Place ice around probe, unit should shut down in one minute. Remove ice from around probe, unit
should start in two minutes.
NOTE: For altitudes over 1000 feet above sea level, adjust range screw (behind end cover). Half turn max.
raises setting 4_F approx.
Figure 3. Icemaker Float Assembly
Water modulating valve (water cooled units only)
—Opening point of condenser water modulating valve should
be set to maintain proper operating pressure in the refrigeration system high side. (see chart on page 13). Closing
point of valve should be set low enough to close valve during compressor stand by periods. To raise, turn
counterclockwise, to lower turn clockwise.
Inlet
Fitting
Low
water
Safety
Band
in
this
direction
to
shutdown
unit
sooner
Bend
down
to
lower
water
level
Band
up
to
raise
water
level