UC 700 Series Continus-Flow Icemaker Installation/Service Manual
Publication Number: 630460127
- 18 -
© 2000-2011, IMI Cornelius Inc.
T
O
R
EPLACE
G
EARMOTOR
A
SSEMBLY
!
WARNING:
Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify all
power is off to the unit before performing any work.
Failure to comply could result in serious injury, death or damage to the equipment.
1.
Disconnect the icemaker from the electrical power source.
2.
Disconnect the transmission cable from the electrical box.
3.
Remove the 4 hex head bolts securing the evaporator to the top of the transmission.
4.
Remove the 4 bolt’s holding the transmission and bracket to frame base, while supporting the weight of the
evaporator. Remove the transmission from the unit.
5.
When replacing the transmission, it may be necessary to rotate the auger back and forth to align the motor
shaft and auger.
Figure 8. Auger And Extruding Head Removal