8. Fault Identification (Continued)
8.9
If the Paddle fails to turn and it is not due to the Top Motor
Assembly seating incorrectly then, providing the motor is being
supplied with power, the motor itself will need changing. See
Section 10.
8.10 Confirm a suspected motor fault by checking the electrical
supply to the motor. Remove the Top Motor Assembly and push
down on the spring loaded section of the Appliance Body Motor
Connector using (insulated) multimeter probes and confirming
mains voltage between the outer metal contact and the inner metal
contact.
Checking for mains supply to the motor