Quest Elite 2000 Installation Manual
Publication Number: 620048922INS
- 10 -
© 2010-2012, IMI Cornelius Inc.
FILLING THE ICE BATH
The ice bath holds approximately 1.62 gallons (6.2 liters) of water. The fill tube is
located behind the front splash plate and capped with a 0.5” plug.
1.
Remove the 0.5” plug and attach the tube to any one of the dispense noz-
zles.
2.
Open the door and verify that the flush/dispense lever is in the dispense
mode. (see Figure 5) Ice bath must always be filled in the dispense mode.
NOTE: Non flush units does not have a flush/dispense lever,
hence for filling water bath on non flush units please
remove the concentrate storage bottles first and then
attach the tube to any one of the dispense nozzles and
close the door, press and hold the dispense button (push)
until the tank is filled and water trickles from the overflow
Figure 5. Water Bath and Dispense/Flush Lever
Dispense/Flush
Lever
Water Bath
Fill Tube
Connection
Water Bath
Overflow
Water Bath
Fill Tube