background image

QUEST ELITE 2000

I

NSTALLATION

 M

ANUAL

Release Date: December 9, 2010

Publication Number: 620048922INS

Revision Date: May 5, 2012

Revision: D

Visit the IMI Cornelius web site at www.cornelius.com for all your Literature needs.

Summary of Contents for Quest Elite 2000

Page 1: ...TE 2000 INSTALLATION MANUAL Release Date December 9 2010 Publication Number 620048922INS Revision Date May 5 2012 Revision D Visit the IMI Cornelius web site at www cornelius com for all your Literatu...

Page 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Page 3: ...g in or on a Counter 3 Requirements 4 Nameplate Data 4 Concentrate Storage 4 Recommended Clearance 5 Electrical Connection 5 Power Supply 5 Water Connection 5 Water Supply Requirements 6 Ice Bank Pull...

Page 4: ......

Page 5: ...ult in serious injury death or equipment damage CAUTION Indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury or equipment damage SAFETY TIPS Carefull...

Page 6: ...isconnect power to the unit before servicing following all lock out tag out procedures established by the user Verify all of the power is off to the unit before any work is performed Failure to discon...

Page 7: ...620048922INS MOUNTING IN OR ON A COUNTER WARNING When installing the unit in or on a counter top the counter must be able to support a weight in excess of 140 lbs 63 5 kg to insure adequate support fo...

Page 8: ...se 60 hertz 6 00 oz 170g R 134a refrigerant Test press High side 400 psi 2757 9 kilopascals 27 6 bar Low side 88 psi 606 7 kilopascals 6 1 bar Model Quest ELITE 2000 230 VAC 2 amps 1 phase 50 hertz 6...

Page 9: ...ter installation CAUTION Only trained and certified electrical technicians should replace the power cord or the unit should be returned to an Authorized Service Center for power cord replacement The r...

Page 10: ...scals 4 1 bar maximum static pressure 30 psi 206 8 kilopascals 2 1 bar minimum dynamic pressure i e flowing pressure measured at dispenser water inlet with 3 0 88 7 ml per second water flow Optimum re...

Page 11: ...e capable of producing a minimum flow rate of 3 fluid ounces 88 7 milliliters per second A shut off valve should be installed in the line before the dispenser Install a regulator in the line when pres...

Page 12: ...e carton for visible damage If damage exists have the carrier make a note on the bill of lading and file a claim with the carrier UNPACKING Remove staples securing carton to pallet Lift carton up and...

Page 13: ...irflow clearance is 4 10 16 cm in back and 12 30 48 cm on top and open to the front IMPORTANT Condenser air is drawn in from the bottom of the rear panel and discharged out the top of the rear panel F...

Page 14: ...ush dispense lever is in the dispense mode see Figure 5 Ice bath must always be filled in the dispense mode NOTE Non flush units does not have a flush dispense lever hence for filling water bath on no...

Page 15: ...press and hold the dispense button push shown in Figure 6 until the tank is filled and water trickles from the overflow Figure 6 Dispense Buttons 4 Once the ice bath is full store the fill tube in the...

Page 16: ...It is the installer s responsibility to ensure that all water connections to the dispenser are sized installed with adequate backflow protection and maintained to comply with Federal State and Local L...

Page 17: ...Manual 2010 2012 IMI Cornelius Inc 13 Publication Number 620048922INS ELECTRICAL A minimum of 15 amps electrical service is needed for 120VAC power supply A minimum of 20 amps electrical service is n...

Page 18: ...d remove air pockets in the system open the cabinet door and make sure that all the valve levers are in the Dispense position Close the door and press the dispense button for a few seconds Repeat unti...

Page 19: ...Extra Large buttons on the Portion Control Module until the Refill light starts blinking Release the buttons The blinking Refill light indicates the programming mode is active See Figure 9 2 Place a c...

Page 20: ...Quest Elite 2000 Installation Manual Publication Number 620048922INS 16 2010 2012 IMI Cornelius Inc...

Page 21: ......

Page 22: ...IMI Cornelius Inc www cornelius com...

Reviews: