11.
Wash the bowl and cover carefully with water and mild
detergent, rinse them well, and replace them, making sure
the sealing strip (E1) is positioned correctly between the
cover and the bowl. To guarantee the seal, the rounded
part of the said sealing strip (as shown in FIGURE 21)
must be facing the cover.
FIGURE 21
12.
Unscrew the fastening knob (F1) clockwise as the
direction indicated by the arrow (threading to the left) and
extract the spiral scraper (G1) and the seals (H1) and (I1).
Clean the individual parts thoroughly (FIGURE 22).
FIGURE 22
13.
Clean the drip tray (J1) and the evaporator (K1) (FIGURE
23).
14.
Replace the mixing unit as follows:
• Dampen the sealing strip (l1) and insert it into its
seating.
• Apply a generous amount of Vaseline (supplied with the
machine) to the suction cup seal (H1) (on the part that
comes into contact with the evaporator K1) and insert it
in its spiral seating.
• Replace the spiral scraper (G1).
• Fasten all the components in place by screwing the
knob F1 counter-clockwise.
FIGURE 23
15.
Replace the bowl by pushing it into its seating.
16.
Fasten the bowl in place by tightening the knobs (A1) -
FIGURE 24 and the locking bar (Z) - FIGURE 16.
FIGURE 24