Ice Frost Operator’s Manual
© 2004-2006, IMI Cornelius Inc.
- 13 -
Publication Number: M620919596OPR
6.
Slide the locking bar (Z) - FIGURE 16 - outwards so that
the bowls are fully released.
Unlock relief valve on the bowl lid cap and remove
(FIGURE 17).
FIGURE 16
7.
Unscrew the knobs (A1) so the bowls can be lowered
slightly, open the tap to remove any remaining liquids and
then extract it from its seating, pulling it outwards (FIGURE
17).
FIGURE 17
8.
Remove the tap from its seating, pressing the two
clamping wings at the same time (FIGURE 18) and
pushing upwards.
FIGURE 18
9.
Remove the tap, holding the body (R) pressed downwards,
then slide the lever (L) out of its seating (FIGURE 19).
Wash all the parts thoroughly with hot water and mild
detergent, rinse them well, and replace them.
FIGURE 19
10.
Separate the bowl from its cover, releasing the fastening
(D1) by pulling them upwards as shown in FIGURE 20.
FIGURE 20
Bowl Lid Cap