TOP ROW
3/8’ - 5/8”
DIMPLE
CENTER
1/8” BRIDGE
BOTTOM 2
ROWS
3/16” - 1/4”
BRIDGE
FIGURE 7. CUBE SEPARATION
12
630460070
Transformer
RD
Error
OFF
OFF
OFF
ON
ON
ON
SW4
SW4
SW4
5
6
YL
YL
YL
YL
S3–1
S3–2
OFF
ON
GR
Comp.
Micro Processor
4 Curtain Switch Connected To Any
Bin Connector (J4–J7) (FACTORY
SETTING AS RECEIVED)
Suction Line Sensor
Bridge thickness pot.
Dump Cycle Dip Switch
Water Curtain
Dip Switch
S3–1
S3–2
On
Off
On
1 2 3
Off
Curtain
Selection
Switch
1
2
3
4
In
Out
Com
Stack
Bin
Switches
External Error LED
Connection
Triac
5 Curtain Switch Must Be Connected To
J4 and J5, J6, J7.
6 Curtain Switch Must Be Connected
To J4, J5, J6 and J7)
SINGLE CURTAIN
DUAL CURTAIN
FOUR CURTAIN
1
S3–1
OFF
ON
2
S3–1
OFF
ON
3
S3–1
OFF
ON
4
S3-1
S3-2
1
OFF
OFF Dump Every Harvest (FACTORY SETTING AS RECEIVED)
2
ON
OFF Dump Every Third Harvest
3
OFF
ON
Dump Every Seventh Harvest
S3–2
S3–2
S3–2
Condenser Sensor
Harvest Voltage Set point pins 2
and 3 Factory setting @ 1.224 V
GR
GR
GR
GR
Fan
Dump
Gear
Gas
Pump
FIGURE 6. DUMP CYCLE OPTIONS
ADJUSTING BRIDGE THICKNESS
For optimum ice production and maximum cube separation, the ice connecting the individual
cubes should be a minimum of 1/8” (.32 cm) thick at the center area of the ice waffle.
BRIDGE 1/8” (0.32 CM)
It is normal for the Ice Bridge to be slightly thicker at the bottom and taper off in a slight wedge
pattern at the top. The top row of cubes must have a complete pattern of ice on all four sides and
the back wall.
REMEMBER: When you operate the product with the panels off during testing the additional heat
at the top of the evaporator will cause thinner ice at the top than when the panels are in place.
Should a different thickness of the bridge be desired, it will be required to adjust the ice thickness
“POT”, located on the circuit board, as follows: