FlavorFusion Installation Manual
Publication Number: 620055764INS
- 16 -
© 2012, IMI Cornelius Inc.
Continued Dispenser Troubleshooting
Symptom
Cause
Remedy
Beverage is too sweet
A. Valve brix requires adjustment
B. Carbonator is not operating
C. No CO
2
in carbonator
D. City water pressure supply low or
inconsistent
A. Adjust valve brix
B. Repair carbonator
C. Restore CO
2
pressure in carbon-
ator
D. Booster pump must be used if
dynamic water pressure drops
below 40 psig.
Unit will not dispense
carbonated drinks.
Dispenses syrup only.
A. CO
2
pressure in carbonator tank
is too high.
B. Water valve will not open
A. Check CO
2
pressure regulator
setting. 75 psig recommended.
Relieve pressure from carbonator
tank.
B. Check electrical connection to
water valve. Check resistance of
coil (should be 9 ohms). Check for
voltage at coil when brand button
is depressed.
Unit will not dispense
carbonated drinks.
Spurts CO
2
and
syrup only.
A. Carbonator tank is empty,
because tank was emptied while
power was applied to unit. 5 min-
ute time-out of carbonator pump/
motor occurred, and carbonator
pump is locked off.
B. Note that this can occur while the
water filter system is serviced or
water supply is shutoff. If drinks
are drawn from the dispenser
while water pressure is shutoff, the
carbonator pump starts and runs
continuously, then shuts off on the
5 minute timeout.
A. Unplug the unit and reconnect the
unit. Main control board will reset,
ice agitation will occur, and car-
bonator tank will refill to normal
level.
B. 1) low water pressure switch deac-
tivates carbonator pump, 2) after 5
minutes reset and retry carbonator
pump. If water supply is restored,
the 5 minute timeout will not occur.
Repeat reset a second time, but
on a third time, then lockout car-
bonator pump, which will gener-
ate a service call.
Carbonated drinks
are flat (low on car-
bonation)
A. CO
2
is out
B. Carbonator tank is 100% filled
because the city water pressure
exceeds the carbonator tank CO
2
pressure regulator setting.
A. Replace CO
2
B. CO
2
setting for the carbonator
tank is 75 psig, max water pres-
sure is 60 psig. If necessary,
install a water pressure regulating
valve.