Adjusting Syrup/Water Ratio (Brix)
Timed Dispense Procedure
1.
Enter programming mode for the valve block by simultaneously pressing and holding both programming
buttons for 4 seconds. The LED’s for flavors 1-4 should flash off and then back on. The drink icon should
turn off.
2.
Set the valve block to a 4 second pour mode by simultaneously pressing and holding Flavor 1 and Flavor
4 buttons until the flash pattern for all for buttons changes.
3.
Place the water end of the ratio cup under the appropriate nozzle and press the left program button for a
4 second dispense of carbonated water. (Push the right program button for still water pour.)
4.
Place the syrup end of the ratio cup under the nozzle and press the appropriate flavor button for a 4 sec-
ond dispense of syrup. The fill line should be the same for both water and the syrup. Adjust the syrup flow
control if necessary, then empty cup and repeat steps 3 and 4.
5.
Repeat for all syrups in valve bank.
6.
Exit 4 second pour mode by simultaneously pressing and holding Flavor 1 and Flavor 4 buttons until the
flash pattern for all for buttons changes.
7.
Exit programming mode by simultaneously pressing and holding both programming buttons for 4 sec-
onds.
Setting a Button to Dispense Non-carbonated Water Only
1.
Program the designated button to dispense non-carbonated water (see Programming Mode.)
2.
Do not connect a syrup source to the inlet circuit of the designated button (1-14 or A1-A2.) If circuit 1
through 14 is chosen leave the coldplate inlet circuit plugged with the red cap. If circuit A1 or A2 is cho-
sen, plug the end of the inlet tube with a red cap from the coldplate, or with tape.
Setting a Button to Dispense Carbonated Water Only
1.
Program the designated button to dispense carbonated water (see Programming Mode.)
2.
Do not connect a syrup source to the inlet circuit of the designated button (1-14 or A1-A2.) If circuit 1
through 14 is chosen leave the coldplate inlet circuit plugged with the red cap. If circuit A1 or A2 is cho-
sen, plug the end of the inlet tube with a red cap from the coldplate, or with tape.
FlavorFusion Installation Manual
© 2012, IMI Cornelius Inc.
- 9 -
Publication Number: 620055764INS
Back Room Package Position (BRP)
E
C D
F
G
J
H
I
C
E
F
D
J
H
I
G
M
K L
N
O
R
P
Q
K
M
N
L
R
P
Q
O
U
S T
V
W
Z
X
Y
S
U
V
T
Z
X
Y
W
Pumps
BIB
Racks
E
C D
F
G
J
H
I
C
E
F
D
J
H
I
G
M
K L
N
O
R
P
Q
K
M
N
L
R
P
Q
O
U
S T
V
W
Z
X
Y
S
U
V
T
Z
X
Y
W
Pumps
BIB
Racks
Figure 5.
NOTE: The ambient circuits A1 and A2 do not give up a cold plate circuit.
Summary of Contents for FlavorFusion
Page 4: ......
Page 24: ...FlavorFusion Installation Manual Publication Number 620055764INS 20 2012 IMI Cornelius Inc...
Page 25: ......