Enduro Ice/Beverage Dispenser Operator’s Manual
4
620916502OPR
PORTION CONTROL PANEL OPERATIONS
Light Color
Explanation
Actions That Can Be Taken
Green
Normal Operation
Press andy
CUP SIZE
for portioned
ice.
--or--
Press
INCREASE
and then
CUP
SIZE
for extra ice.
Green
--
flashing
Normal Operation Chute Refil-
ling
Wait until chute has refilled and press
desired
CUP SIZE
again.
Red
then
Yellow
Clean Mode
To enter Clean Mode simultaneously
press
INCREASE
and
DECREASE
.
Press any
CUP SIZE
to empty chute,
then remove chute for cleaning.
When chute is replaced, unit automat-
ically returns to normal operation after
one minute, or
INCREASE
and
DE-
CREASE
can simultaneously pressed
3 times.
ICE PORTION CONTROL SETUP AND ADJUSTMENT PROCEDURE
Light Color
Explanation
Actions That Can Be Taken
Step 1. Fill the Ice
Chute
Yellow Flashing
Chute Agitation Refill Time
To enter Agitation Adjustment Mode
simultaneously press
INCREASE
and
DECREASE
three times then
press and hold
INCREASE
and
DE-
CREASE
for 3 seconds.
Press any
CUP SIZE
to select a
preset agitation time (small=short-
est time, X--Large=longest time,
ect)
To exit Agitation Refill Time Adjust-
ment Mode simultaneously press
INCREASE
and
DECREASE
.
NOTE:
Once in a mode the light
blinks to indicate the refill time: 1
blink for the shortest refill time and
4 blinks for the longest refill. The
factory recommendation is 2 blinks.
NOTE:
Larger ice portions require
more time to refill.
Summary of Contents for Enduro ED-250 BCP
Page 15: ...IMI CORNELIUS INC...