Cornelius ENDURO-175 Installation Manual Download Page 2

The products, technical information, and instructions contained in this manual are subject to change without notice. 
These instructions are not intended to cover all details or variations of the equipment, nor to provide for every possi-
ble contingency in the installation, operation or maintenance of this equipment. This manual assumes that the per-
son(s) working on the equipment have been trained and are skilled in working with electrical, plumbing, pneumatic, 
and mechanical equipment. It is assumed that appropriate safety precautions are taken and that all local safety and 
construction requirements are being met, in addition to the information contained in this manual.

This Product is warranted only as provided in Cornelius’ Commercial Warrant applicable to this Product and is sub-
ject to all of the restrictions and limitations contained in the Commercial Warranty.

Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting 
from any of the following occurrences, including but not limited to, (1) other than normal and proper use and normal 
service conditions with respect to the Product, (2) improper voltage, (3) inadequate wiring, (4) abuse, (5) accident, 
(6) alteration, (7) misuse, (8) neglect, (9) unauthorized repair or the failure to utilize suitably qualified and trained per-
sons to perform service and/or repair of the Product, (10) improper cleaning, (11) failure to follow installation, oper-
ating, cleaning or maintenance instructions, (12) use of “non-authorized” parts (i.e., parts that are not 100% 
compatible with the Product) which use voids the entire warranty, (13) Product parts in contact with water or the 
product dispensed which are adversely impacted by changes in liquid scale or chemical composition.

Contact Information:

To inquire about current revisions of this and other documentation or for assistance with any Cornelius product con-
tact:

www.cornelius.com

800-238-3600

Trademarks and Copyrights:

This document contains proprietary information and it may not be reproduced in any way without permission from 
Cornelius.

Printed in U.S.A.

Summary of Contents for ENDURO-175

Page 1: ...EVERAGE DISPENSER MODEL ENDURO 175 8 VALVE Release Date March 24 2004 Publication Number 620917902INS Revision Date August 3 2010 Revision D Visit the IMI Cornelius web site at www cornelius com for a...

Page 2: ...rvice required by or loss or damage resulting from any of the following occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Pr...

Page 3: ...t Open Or Is Sluggish Agitator Turns 11 ice Dispenses Continuously 11 Slushy Ice Water In Hopper 11 Beverage Does Not Dispense 11 Beverage Too Sweet 11 Beverage Not Sweet Enough 11 Beverage Not Cold U...

Page 4: ...or moderate injury or equipment damage SAFETY TIPS Carefully readandfollowall safety messagesinthismanualandsafety signsontheunit Keepsafety signsin goodconditionandreplace missingordamageditems Learn...

Page 5: ...will cause residual sanitizing solution or water remaining inside the unit to freeze resulting in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention...

Page 6: ...n several flavors of post mix beverages BC units include beverage faucets and a cold plate and are designed to be supplied direct from syrup tanks and carbonator with no additional cooling required SP...

Page 7: ...cord are routed through the large opening in the bottom of the unit See the MOUNTING TEMPLATE Figure 2 for locating the required clearance opening in the counter for these utility lines 3 DRIP TRAY DR...

Page 8: ...a specific time i e 2 seconds 3 NOTE water and syrup must be cold before checking the ratios 4 Adjust carbonated water flow to the desired rate such as 90 to 110 ml 3 to 3 75 oz per second Turn the f...

Page 9: ...removing or adjusting restrictor See safety section of this Manual Figure 1 Gate Restrictor Plate ADJUSTMENT This plate may be adjusted as shown to reduce or increase the dispensing rate of ice espec...

Page 10: ...lation Manual Publication Number 620917902INS 7 2004 2010 IMI Cornelius Inc COMMENDED COUNTER OPENING SIZE 9 X 12 FOR UTILITIES AND BEVERAGE TUBING OPENING CAN BE LOCATED ANYWHERE WITHIN THE SHADED AR...

Page 11: ...Ice Beverage Dispenser Installation Manual 2004 2010 IMI Cornelius Inc 8 Publication Number 620917902INS Figure 3 Drip Tray Drain Assembly...

Page 12: ...Ice Beverage Dispenser Installation Manual Publication Number 620917902INS 9 2004 2010 IMI Cornelius Inc FAUCETS VIEWED FROM THIS SIDE Figure 4 Flow Diagram Bc Models With Eight Beverage Faucets...

Page 13: ...Ice Beverage Dispenser Installation Manual 2004 2010 IMI Cornelius Inc 10 Publication Number 620917902INS Figure 5 Flow Diagram B Models With Eight Beverage Faucets...

Page 14: ...obable Cause BLOWN FUSE OR CIRCUIT BREAKER A Short circuit in wiring B Defective gate solenoid C Defective agitator motor GATE DOES NOT OPEN AGITATOR DOES NOT TURN A No power B Bent depressor plate do...

Page 15: ...B No CO2 pressure C Empty syrup tank D Kinked tubing E Clogged inner nozzle F Defective PC board G Defective harness from keypad H Defective Flow control I Defective solenoid harness J Defective keyp...

Page 16: ...Ice Beverage Dispenser Installation Manual Publication Number 620917902INS 13 2004 2010 IMI Cornelius Inc Figure 6 Wiring Diagram 120V...

Page 17: ...Ice Beverage Dispenser Installation Manual 2004 2010 IMI Cornelius Inc 14 Publication Number 620917902INS Figure 7 Wiring Schematic 120V...

Page 18: ...Ice Beverage Dispenser Installation Manual Publication Number 620917902INS 15 2004 2010 IMI Cornelius Inc Figure 8 Wiring Diagram 220 240V UNI...

Page 19: ...Ice Beverage Dispenser Installation Manual 2004 2010 IMI Cornelius Inc 16 Publication Number 620917902INS Figure 9 Wiring Schematic 220 240V...

Page 20: ......

Page 21: ...IMI Cornelius Inc www cornelius com...

Reviews: