Cornelius CR 11 Manual Operation Download Page 4

 

 

CR R134a Range

 

 

 

Manual operation undercounter cooler 

CR R134a 

Page 4 

 

Cornelius Deutschland GmbH 
Document no: TD1004600EN 
Version A, 24.09.2019, Index 0 

Safety 

 

1.1 

Intended use 

 

By using the unit as intended you will not only protect yourself, but also prevent damage occurring to the unit 
and its components! 
 
The intended use of under counter coolers from the CR 

R134a series (referred to as “unit” in the following) is to 

refrigerate and convey non-alcoholic beverages and their basic ingredients. CO2 or electric pumps are used as 
conveying equipment for the brands. 
The unit is only suitable for stationary installation in a closed room. Stationary installation is to be carried out by 
an expert in compliance with all of the specifications given this manual 

The intended use means that you will carry out all activities with and on the unit to the specifications provided in 
this document. 
This unit is only to be operated by those who meet the requirements set out in this document. 
Work on the unit and its components not included in the activities described in this document may only be 
performed by experts, means authorized and skilled people. 
 
User manual can also be down loaded at website: 

www.cornelius-emea.com

 

 

 
1.2 

Improper use 

 

Improper use of the unit and unauthorized modifications to the unit and its components may cause personal 
injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability. Improper use of 
the unit is prohibited. 

 

The following in particular is regarded as improper use: 
 

 

-

 

Mobile operation of unit 

-

 

Operation of unit in areas without supervision by skilled personnel 

-

 

Operation of the unit in an area, where water jet is possible. 

-

 

Cleaning with a water jet 

-

 

Any handling as e.g. use or service by children under the age of 8 years 

-

 

Any cleaning or service by children without supervision by a skilled, authorized adult. 

-

 

Use by persons (including children) with physical, sensory or mental disabilities or those with insufficient 
experience and knowledge, unless they are supervised by a person responsible for their safety, or this 
person has instructed them in the use of the unit. 

-

 

Use by those under the influence of medication, alcohol, drugs or other substances which impair their 
physical, sensory or mental abilities. 

-

 

The refrigeration of non-specified liquids and those above the maximum supply temperatures as this may 
cause unacceptably high pressures to build up in the refrigeration circuit. 

-

 

Operating the unit below the minimum and above the maximum ambient temperatures (minimum and 
maximum temperatures see chapter 3.3, page 15). 

-

 

Operating the unit with conveying media other than those defined in this document. 

-

 

Operating the unit in locations and ambient conditions which do not fully meet the requirements of this 
manual 

-

 

Operation of the unit by untrained staff 
 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for CR 11

Page 1: ...CR R134a Range Manual Operation...

Page 2: ...n status Index 0 Protection notices in accordance with DIN ISO 16016 2002 5 The reproduction distribution and utilization of this document as well as the communication of its contents is prohibited un...

Page 3: ...quirements 9 3 1 Installation Sites 9 3 2 Electrical Connections 9 4 Installation 9 4 1 Connection of Soda water Still water Premix beverages and Postmix syrups 9 4 2 Connection of Beer 9 4 3 Connecti...

Page 4: ...s components may cause personal injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability Improper use of the unit is prohibited The following in particular is regarde...

Page 5: ...owledge of relevant standards laws regulations accident prevention regulations generally accepted safety related regulations and operating conditions to be able to perform the required activities as w...

Page 6: ...formation on occupational safety for the safe operation of dispensing systems as applicable in the respective country of installation Notice o Make sure that the cable markers are not removed from the...

Page 7: ...sture entering a unit as well as certain weather conditions e g condensate forming at the unit sunlight will cause damage to the unit and its components Protect the unit and its components by storing...

Page 8: ...e fully drained from the unit 2 2 Disposal Disposal of the units must be carried out in compliance with the applicable local and or national and international regulations Units must not be disposed of...

Page 9: ...The unit must be installed by a trained service technician Please take care that the socket for the unit is always accessible If the power supply cable to the unit is damaged it has to be replaced by...

Page 10: ...he agitator motor Reference Use for this a suitable funnel and filler tube To prevent algae from forming in the water add the disinfectant Molco PN 14 9670 150 The 150 ml container of disinfectant is...

Page 11: ...nly by operator Check whether carbon dioxide is open Check the beverage lines for leaks Only a visual inspection is possible If liquid escapes call a service technician Check the CO2 lines for leaks b...

Page 12: ...e of beverage X X X Before and after a pause of more than 1 week X X X X Weekly X Every 2 weeks X Every 3 months X X Every 12 months X 6 2 Cleaning and Disinfection Procedure before use In order to ac...

Page 13: ...ched with CO2 Connect container with fresh basic material Beverage foams at all taps CO2 pressure too high Set pressure All syrups Connect container enriched with CO2 with fresh basic materials All be...

Page 14: ...604 W 800 W 1512 W 1512 W 2400 W 2400 W 2400 W Air flow 160 m3 h 300 m3 h 570 m3 h 570 m3 h 1700 m3 h 1700 m3 h 1700 m3 h Compressor output 245 W 395 W 684 W 684 W 1437 W 1437 W 1437 W Weight of ice b...

Page 15: ...R134a Range Manual operation undercounter cooler CR R134a Page 15 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 9 Flow Chart 9 1 Premix and Beer units 9 2 Postmix un...

Page 16: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 16 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 10 Circuit Diagram...

Page 17: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 17 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 11 Declaration of Conformity Konformit tserkl rung...

Reviews: