CR R134a Range
Manual Operation
Page 1: ...CR R134a Range Manual Operation...
Page 2: ...n status Index 0 Protection notices in accordance with DIN ISO 16016 2002 5 The reproduction distribution and utilization of this document as well as the communication of its contents is prohibited un...
Page 3: ...quirements 9 3 1 Installation Sites 9 3 2 Electrical Connections 9 4 Installation 9 4 1 Connection of Soda water Still water Premix beverages and Postmix syrups 9 4 2 Connection of Beer 9 4 3 Connecti...
Page 4: ...s components may cause personal injury and equipment damage for which Cornelius Deutschland GmbH shall assume no liability Improper use of the unit is prohibited The following in particular is regarde...
Page 5: ...owledge of relevant standards laws regulations accident prevention regulations generally accepted safety related regulations and operating conditions to be able to perform the required activities as w...
Page 6: ...formation on occupational safety for the safe operation of dispensing systems as applicable in the respective country of installation Notice o Make sure that the cable markers are not removed from the...
Page 7: ...sture entering a unit as well as certain weather conditions e g condensate forming at the unit sunlight will cause damage to the unit and its components Protect the unit and its components by storing...
Page 8: ...e fully drained from the unit 2 2 Disposal Disposal of the units must be carried out in compliance with the applicable local and or national and international regulations Units must not be disposed of...
Page 9: ...The unit must be installed by a trained service technician Please take care that the socket for the unit is always accessible If the power supply cable to the unit is damaged it has to be replaced by...
Page 10: ...he agitator motor Reference Use for this a suitable funnel and filler tube To prevent algae from forming in the water add the disinfectant Molco PN 14 9670 150 The 150 ml container of disinfectant is...
Page 11: ...nly by operator Check whether carbon dioxide is open Check the beverage lines for leaks Only a visual inspection is possible If liquid escapes call a service technician Check the CO2 lines for leaks b...
Page 12: ...e of beverage X X X Before and after a pause of more than 1 week X X X X Weekly X Every 2 weeks X Every 3 months X X Every 12 months X 6 2 Cleaning and Disinfection Procedure before use In order to ac...
Page 13: ...ched with CO2 Connect container with fresh basic material Beverage foams at all taps CO2 pressure too high Set pressure All syrups Connect container enriched with CO2 with fresh basic materials All be...
Page 14: ...604 W 800 W 1512 W 1512 W 2400 W 2400 W 2400 W Air flow 160 m3 h 300 m3 h 570 m3 h 570 m3 h 1700 m3 h 1700 m3 h 1700 m3 h Compressor output 245 W 395 W 684 W 684 W 1437 W 1437 W 1437 W Weight of ice b...
Page 15: ...R134a Range Manual operation undercounter cooler CR R134a Page 15 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 9 Flow Chart 9 1 Premix and Beer units 9 2 Postmix un...
Page 16: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 16 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 10 Circuit Diagram...
Page 17: ...CR R134a Range Manual operation undercounter cooler CR R134a Page 17 Cornelius Deutschland GmbH Document no TD1004600EN Version A 24 09 2019 Index 0 11 Declaration of Conformity Konformit tserkl rung...