IntelliCarb Drop-In Ice Cooled Installation Guide
© 2003-2017, Cornelius Inc.
- 37 -
Publication Number: 630460204INS
Pump runs continuously
(Cont’d)
D. Overdrawing.
D. Check capacity of pump. The
combined rate of flow from dis-
pensing valves should not exceed
the stated GPH for pump, or
pump will run continuously.
Noisy pump
A. Bad motor bearings or worn pump
shaft.
B. Failure of Triac on liquid level con-
trol.
C. Insufficient water supply.
A. Repair or replace motor.
B. Repair or replace liquid level con-
trol.
C. Check that water supply is on.
Also check for clogged water filter,
ruptured tank or bad double
check valve.
Valve delivers
co
2
gas continu-
ously
A. Pump motor will not run.
B. Pump water supply restricted.
C. Relief valve venting.
D. Worn pump.
A. See Pump Motor Will Not Run.
B. Clean strainer. Check for faulty
double check valve.
C. Repair or replace.
D. See Pump Motor Will Not Stop.
Valve delivers soda water and
co
2
gas intermittenly
A. Pump water supply restricted.
B. Relief valve venting.
C. Inefficient or worn pump.
A. Clean strainer. Check for faulty
single check valve, clogged water
filter, water supply off or blocked,
ruptured tank, faulty liquid level
control or double check valve.
B. Replace or repair.
C. See Pump Motor Will Not Stop.
Poor Carbonation
A. Flooded carbonator.
B. Water temperature too high
(warm).
C. Oil in water supply.
D. Supply water containing too much
air in solution.
E. Poor quality paper cups.
F. Dirty or greasy glassware.
G. Excessive foam.
H. Flat drinks.
A. See Pump Motor Will Not Run.
B. Check water inlet temperature.
Lower temperature provides bet-
ter carbonation.
C. Check pipe thread compound.
Remove and clean and replace
with PTFE pipe thread tape.
D. To remove air before it enters
pump, it will be necessary to
install an open tank with float to
control water level.
E. Purchase quality cups made for
this application.
F. Wash all glassware.
G. CO
2
BIB pump pressure too high,
contamination within the bever-
age system, poor quality paper
cups or dirty glassware.
H. Draw drinks against side of glass
or cup. Check for insufficient CO
2
contamination, bad check valve,
ruptured CO
2
line
TROUBLESHOOTING for Carbonator
Trouble
Probable Cause
Remedy
Summary of Contents for CB1522