Replacing GIB Controller on Quest Juice Dispensers

© 2003-2011, IMI Cornelius Inc.

- 3 -

Publication Number: 729011138INS

9.

Remove plugs from GIBC by pulling connectors from rear of unit. Plugs may be difficult to remove. (NEVER 
PULL ON WIRES AS THEY MAY COME LOOSE FROM CONNECTOR BODY). If connector body is damaged 
replace with the proper connector body supplied in the kit. Refer to the drawing in the beginning of the installation 
sheet for proper connector and wire locations.

10.  Reverse the above procedure to reassemble machine.

CAUTION:  When reinstalling the new GIBC be sure not to pinch wires between any parts of the 
frame. With the side panel off inspect that the wires are free and not trapped where they could 
become pinched and short out to the cabinet frame.

NOTE: It is also recommended that before reattaching the panels to the machine reinstall the control 

and verify machine functions properly. If any part of the dispenser does not function properly 
such as pumps, disconnect power and reinstall GIB control. Be sure connector is seated prop-
erly in connectors.

7.

Locate the electrical box, from the front of the machine, and 
remove the screw on the right side holding it in place. Grab 
the left tab of the box and pull forward.

NOTE: The connectors in the back will tend to give 

some resistance when pulling on the box.

8.

You will now be able to access the GBIC. To remove slide 
module to the right. When box stops push up and pull for-
ward. 