66
326142000
Trouble
Remedy
Probable Cause
FROZEN PRODUCT
CONSISTENCY VARIES
EXCESSIVELY.
A.
Dispensed product BRIX
varying because:
A.
Syrup and/or water flow
regulator sticking.
a.Clean regulator(s).
Primary CO
2
regulator pressure
insufficient.
b.Primary CO
2
regulator must be
adjusted from 80 to 100-psi.
B.
Cylinder freeze–up causing ice
formation in center of cylinder
and liquid product channels
around ice formation.
B.
Refer to CYLINDER
FREEZE–UP.
NOTE: DEFROST AFFECTED FREEZE CYLINDER AS
INSTRUCTED.
CYLINDER FREEZE–UP.
A.
Dispensed product BRIX too
low.
A.
Refer to BRIX (Water-to-Syrup)
‘‘Ratio’’ too low.
B.
Viscosity of dispensed product
not properly adjusted.
B.
Adjust dispensed product
viscosity as instructed
ACCESSORIES AND TOOLS
ACCESSORIES
1155
Installation Kit
511005000
Cup Holder
511006000
Cup Holder
511035000
CO
2
Changeover Kit
1040
Seal Kit, Rear O–Ring Housing and O-Rings
GENERIC FLAVOR TABS
1085
Cola
1086
Cherry
1087
Orange
1088
Grape
1089
Lemon–Lime
1090
Strawberry
1091
Banana
SERVICE TOOLS
151689000
Spanner Wrench, Flow Regulator
281884000
3-gallon Sanitizing Tank
322859000
Spanner Wrench, Dispensing Valve
511004000
Refractometer, 0–30 Scale
322063000
Shaft Seal Assembly Puller
0726
Alignment Tool Kit, Beater Drive Shaft Ass’y
Summary of Contents for 326142000
Page 23: ...16 326142000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 33: ...26 326142000 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 37: ...30 326142000 FIGURE 5 OPERATING CONTROLS ...
Page 38: ...31 326142000 FIGURE 6 UNIT INTERNAL COMPONENTS ...
Page 59: ...52 326142000 FIGURE 12 WATER STRAINER SCREEN AND DOUBLE LIQUID CHECK VALVE ...
Page 66: ...59 326142000 FIGURE 16 REFRIGERATION FLOW DIAGRAM ...
Page 67: ...60 326142000 FIGURE 17 WIRING DIRGRAM ...
Page 77: ...326142000 70 4 5 6 7 8 11 12 14 15 79 84 85 87 88 115 117 118 4 FIGURE 20 FCB FLOW DIAGRAM ...
Page 86: ...79 326142000 THIS PAGE LEFT BLANK INTENTIONALLY ...