16
166240008
3/17/95
Cycle time (CT) = freeze time plus harvest time, in minutes and seconds. 1440 divided by CT = number of
cycles per 24 hours.
Measure weight of ice from one cycle in pounds and fractions of a pound.
Example: Weight/cycle x cycles/day = total production/24 hrs. Compare to the production tables
* If water cooled, be certain water regulator valve is set to maintain 225/235 PSI head pressure.
YL
YL
RH Evap.
Water
Dump
Valve
Contactor
Water
Pump
1
3
5
7
2
4
230v
115v
Voltage
Selector
Switch
GR
LH Evap.
Condenser
plug
Suction plug
Test
Plug
Options
Plug
Adjustable Ice
Thickness Pot.
Micro Processor
Stacking
Cable
Plug
Manual
Harvest
Switch
Transformer
To Stacked Unit
(if required)
Fan
GR
RD
Error
Condenser Sensor
Suction Line Sensor
RH Evap. Switch
LH Evap. Switch
6
8
neutral
D-15
D-13
D-14
D-12
D-10
Hot Gas
D-11
D-6
D-5
White
Brown
LED INDICATORS
The LEDs are board circuit indicators. If the LED in the functional board circuit is complete, check component.
Example: Contactor does not energize and LED is “ON”, board circuit is OK. Check contactor, coil, leads, &
connections.
Yellow:
S
Evaporator switch(s) (proximity)
Green:
S
Water dump valve
S
Compressor contactor
S
Water Pump
S
Hot Gas Valve
S
Condenser Fan (cycles on & off with fan)
Red:
Error in system operation. Product shut down.