6.

 

CONNECTING THE DEVICE: 

 

Only  turn  on  the  device  with  the  „on”  button  when  you  already  connected  the 
necessary cables (power cord, USB Input, AES/EBU, SPIDF, i2S output) to the right 

input or outputs of all devices. 

 
The maximum lenght of the USB cable cannot exceed 3 meters! We recommend a 

cable between 1 and 2 meters. With the AES/EBU and SPDIF cables we recommend 
maximum 3 meters. 

 
Never use cables with damaged cover or damaged plugs or with faulty connections 

 
 Proper order of turning on equipments: 

o

 

KARUNA USB/SPIDF converter and reclocker 

o

 

Source device 

o

 

Digital/analog converter 

o

 

Active speakers or amplifiers 
 

     The turning on of the USB/SPIDF converter should ALWAYS be performed before 

                       the  turning  on  of  the  source  device  -  otherwise  the  source  device  might  not 

                       recognize the converter or it’s operation system might crash. 

 

Never  unplug  the  device  from  the  source  or  the  DAC  during  playing  because  the 

device can be physically damaged  
 

Wrecking or taking off the cover of the device while it is connected to electricity is 
Forbidden and can result in death. 

 

 

 

 

 

 

 

 

 

Summary of Contents for KARUNA P24

Page 1: ...CORE AUDIO KARUNA P24 USB SPDIF converter reclocker Core Audio Kft Hungary All rights reserved 19 05 2021 www coreaudio eu CORE AUDIO KARUNA P24 USB SPDIF converter reclocker USERS MANUAL...

Page 2: ...rights reserved 19 05 2021 www coreaudio eu CONTENT 1 Introduction 2 Product Description 3 Content of the package 4 Technical specifications 5 Installation guide Driver 6 Connecting the device 7 Warr...

Page 3: ...erred to the digital analog converter by our USB SPDIF transformer with minimal loss of information or transformation We believe our goals set when creating the products were necessary because the dig...

Page 4: ...built with 3 circuits linear PSU We use short and optimized PCB conduction bands For the external power we use a high quality standard Furutech IEC socket with changeable fuse The standard inside cab...

Page 5: ...ates in different principles than the original Front and top of the device On the front panel of the device there is the On off switch with a LED indicator To turn the converter on you have to press t...

Page 6: ...the source through this cable AES EBU XLR output symmetric output suitable to connect 110 ohm cable S PDIF RCA output output suitable for connecting 75 ohm cable 24MHz Clock OUT miniXLR sockets the e...

Page 7: ...ther P24 Serie equipment General Technical Specifications Voltage 220 240 V 50Hz Power consumption max 10 W Digital Outputs AES EBU XLR S PDIF RCA Digital Inputs USB 2 0 type B Clock signals 3 1db 44...

Page 8: ...stributions already contain the necessary XMOS drivers to connect the USB we recommend that you use the device with the driver provided by us that way we can guarantee the problem free operation of th...

Page 9: ...KARUNA P24 USB SPDIF converter reclocker Core Audio Kft Hungary All rights reserved 19 05 2021 www coreaudio eu d Accept Terms and Conditions tick the square and click Next e Selecting the Installati...

Page 10: ...CORE AUDIO KARUNA P24 USB SPDIF converter reclocker Core Audio Kft Hungary All rights reserved 19 05 2021 www coreaudio eu f Finish Installation...

Page 11: ...o Kft Hungary All rights reserved 19 05 2021 www coreaudio eu g Close Installing Wizard h At the Settings menu of the media player applications you can choose what audio device you want to use Since t...

Page 12: ...21 www coreaudio eu i Connect the USB cable from the source to the device and turn it on The following text will pop up in the bottom right corner of the screen j At this point you can select xCore US...

Page 13: ...3 meters Never use cables with damaged cover or damaged plugs or with faulty connections Proper order of turning on equipments o KARUNA USB SPIDF converter and reclocker o Source device o Digital anal...

Page 14: ...rs in order to conserve the lifespan of the built in clock signal generators Optimal cable connections Symmetric connection with AES EBU XLR cables Digital coax connection with S PDIF RCA connecting c...

Page 15: ...is equal The right clockcable is assembled with miniXLR mother miniXLR father b Music Server assembled with Core Audio USB P24 card DENPO P24 DAC KARUNA P24 will work as Masterclock for Music Server...

Page 16: ...minated The Core Audio Kft company will refuse to repair it take it back or switch it to a new one The Core Audio Kft will not take responsibility for any defects or damage resulting from accident fal...

Page 17: ...USB 2 0 Audio set as your primary audio device c Device doesn t connect to DAC Check if USB SPIDF device is connected to electricity and is turned on Check the DAC if it is connected to electricity an...