R_077 REV.8 ott. 2017 P. 4 di 11
1.
General information
The instructions for use referred to in this document refer to the electric
radiators and in particular to the models:
CLAUDIA ELEKTRISCH
Height
[mm]
Width
[mm]
Power [W]
400
760
400
500
760
500
600
760
600
400
1190
600
500
1190
700
600
1190
900
400
1400
700
500
1400
900
600
1400
900
400
1800
900
500
1800
900
600
1800
1200
2.
Technical characteristics
Electric radiators standard version:
•
Class I Insulation
•
Protection: IP 44
•
Internal operating thermostat set to 90 - 100 °C
•
Safety overheating fuses set to 152°C
These radiators are factory primed with a clearly specified amount of
special fluid ensuring heat transmission.
If any of these fluids leaks out, the radiator must be restored to optimum
working conditions by the manufacturer, a person delegated by the
manufacturer or a person with suitable qualifications, to ensure that proper
operating and safety conditions are restored.
3.
Notice for the end user
To clean coloured radiators, use only non-abrasive cloth dampened with
water.
To clean the stainless steel radiators you can use a non-abrasive cloth
dampened with water and methyl alcohol diluted to 50%. Do not use
detergents or aggressive substances. Avoid any acidic or basic solutions,
industrial chemicals or other substances, corrosive or abrasive materials
(bleach, ammonia, soda ...) Do not use abrasive sponges or cloths.
4.
Notice for the installer
The product purchased is subject to the general rules of warranty so as
written in the official Catalogue in force. The warranty starts from the date of
delivery and is void if the indication of the production lot is modified and / or
removed. The guarantee shall be effective after examination of the defects
and their relevant causes. The material to replace or repair must be
delivered at the retailer warehouse. The obligation to provide the guarantee
is subject to the conditions and requirements set out below.
The radiator has not been damaged during shipping, handling or installation
and any repairs and / or modifications have been carried out by a third
party, if not expressively authorized by the manufacturer. The material has
been stored in good condition and protected from the weather before being
installed. The installation of this product should be performed by qualified
personnel and in accordance with these instructions and all safety
equipment rules both national and local. Do not place the radiators in rooms
with the presence of chlorine vapours or corrosive fumes such as swimming
pools saunas, spa tubs.
5.
Instructions for installation in Bathroom
The national rules on installing electrical equipment in the bathroom must
be scrupulously respected. The electric radiators must be always installed
outside zone 1 and 2.
In particular the electric switch and control elements most be mandatory
located in zone 3, in order that no electrical control center is accessible to
anyone using the shower or bath.
.
Install the radiator in such a way that the minimum distance between the floor
and the thermostat is 250mm and make sure that there are no obstacles
within a minimum distance of 100mm from the appliance.
6.
Wall mounting
The electric radiators must be mounted on the wall following the instructions
provided in the packaging of fastening supports.
When the radiator is in the proper position, the resistor is located at the
bottom right.
The radiator must absolutely never be installed with the resistor turned
upwards or in any direction other than pointing downwards, as the heating
element in the resistor itself would be irreversibly damaged during operation.
Never position the radiator in front of the power socket.
Make sure that the resistor never operates unless it is fully submerged.
7.
Connecting up
All models of electric radiator are fitted with a power cable complete with a
pre-mounted Shuko plug. Before connecting up, make sure that the rated
voltage of the appliance (230V) corresponds with the mains voltage, and also
check to ensure that the wall socket is properly earthed in compliance with
current regulations and that it is capable of delivering the rated current
required to operate the chosen model at full power.
8. Cautions
Operating instructions for
Electric Radiators
Claudia
EcoDesign Digi with digital
thermostat