RFID
ANALYSIS
•
When an RFID tag is located an RFID details
menu will be displayed which shows the
hexadecimal identification of the RFID tag.
•
It is recommended that an alias is then
added for future identification the tag
location . Use the joystick to highlight the
alias section (complete with selecting OK)
and then input a simple description through
the qwerty options (complete with selecting
OK - this can be edited later in CorDEX
CONNECT)
•
Select whether the RFID Tag is built into
a CorDEX IR window (IW2000, IW3000,
IW4000) or if it is a stand alone tag (NON
CDX).
•
With the RFID tag editing complete select
SAVE to store this information for future use.
There are three settings in the analysis menu:
1
The No. spots icon allows choice of 0, 1, 2 or
3 temperature spots (crosshairs) within the
display that will update in real time
2
The Hi icon enables and disables display of
maximum temperature within the image as a
red spot (crosshair). This temperature will be
the same as the top of the temperature range
in auto span/level.
3
The Lo icon enables and disables display of
minimum temperature within the image as a
blue spot (crosshair) This temperature will be
the same as the bottom of the temperature
range in auto span/level.