background image

2

 ED 4200, ED4200S

 For Narrow Stile Metal Doors of Either

 Hand

 ED 4200M, ED4200MA, ED4200S,

 ED 4200SMA

 For Metal, Composite and Wood Doors of 

 Either Hand

Shim Kit Option

Kit consists of (2) Latch Head Shims 

(Device Cover seats on shim) and (2) 

End Cap Shims (End Cap Shims (End 

Cap seats on shim).

Each shim is 1/8ʼ (3.2mm) thick.

More than two shim thicknesses 

1/4” (6.4mm), require longer device 

mounting screws (not included).

Device

Rim Qty

SecureBolt  Qty

Size

(No Trim)

4

6

1/4 - 20

(With Trim)

2

2

1/4 - 20

Fire Mullion (Add)

4

4

10 - 24

Recommended for un-reinforced metal doors.

        Standard for Fire Rated Doors.

Maintenance

1. Periodically remove covers and coat mechanisms with a 

silicone base lubricant.  This is particularly required in 

corrosive environments for proper product function.

2. Check mounting fasteners periodically.  Retighten if 

found loose.  Apply screw looking compound (available 

at automotive part stores) or change part fasteners if 

screws continue back up.

3. Periodic checks and adjustments of strike are required to 

compensate for changes in the opening (e.g.; door 

sagging, etc....).

General Information

Specify Finish

697F35-8, Black Finish

®

Summary of Contents for Rim & SecureBolt ED4200 series

Page 1: ...component Packed for reinforced metal doors Optional sex nuts required for unreinforced metal and composite wood doors and are furnished standard with all re rated A devices Outside Trim Device is pa...

Page 2: ...0 With Trim 2 2 1 4 20 Fire Mullion Add 4 4 10 24 Recommended for un reinforced metal doors Standard for Fire Rated Doors Maintenance 1 Periodically remove covers and coat mechanisms with a silicone b...

Page 3: ...Minimum Door Stile 2 50mm ED4200M ED4200MA ED4200SM ED4200SMA Minimum Door Stile 3 1 2 89mm Door and Frame must meet structural and dimensional speci cations on exit device template s for door and fr...

Page 4: ...4 A 1 1 4 32mm B 3 4 29mm ED4200 ED4200S with 808 Mullions ED4200M ED4200MA ED4200SM ED4200SMA with 700 900 Mullions with 650F308 strikes...

Page 5: ...5 ED4200M ED4200MA ED4200SM ED4200SMA ED4200 ED4200S Caution The Use of Shims i e Raised Glass requires shifting location of strike away from the door See Door Marker Template for details...

Page 6: ...6 For ED4200 ED4200S Sof t to Cutoff...

Page 7: ...vice mounting screws needed when more than 2 shim kits are used See Shim Kits Option on page 2 When resulting operation is faulty check rst for visible binding or interference If there is no apparent...

Page 8: ...8 ED4200 ED4200S...

Page 9: ...9 ED4200M ED4200MA ED4200SM ES4200SMA 3 10 24 PFHMS Use 8 32 PFHMS screws 2 for Cover and 3 for End Cap...

Page 10: ...uction Sheets Must Be Used On The Bottom of The BACK PAGE OR BACK COVER Of All Multiple Page Installation Instruction Sheets Copy Can Be Typed Copyright 2008 Corbin Russwin Inc an ASSA ABLOY Group com...

Page 11: ...uction Sheets Must Be Used On The Bottom of The BACK PAGE OR BACK COVER Of All Multiple Page Installation Instruction Sheets Copy Can Be Typed Copyright 2008 Corbin Russwin Inc an ASSA ABLOY Group com...

Page 12: ...Instruction Sheets Group Brand Tagline Must Be Used On The Bottom Left Of ALL ONE PAGE Installation Instruction Sheets Must Be Used On The Bottom Left Of ALL INSIDE PAGES of Multiple Page Installatio...

Reviews: