Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
700
™
TCPWI1
6) Operational Check
IMPORTANT: Be sure to test functions prior to closing door.
In all cases, perform the following checks:
1. Ensure that inside lever retracts latch (and deadbolt for deadbolt functions).
• For devices with cylinders, the following checks apply:
Insert key into cylinder and rotate:
a. There should be no friction against lock case, wire harness, or any other
obstructions. If harness friction exists, refer to the section on Installation
of Inside Components.
b. The key should retract the latch and the key should rotate freely.
c. The key should extend and retract the latchbolt.
• For units without a keypad, the following checks apply:
Insert test card marked NO PIN and retract:
a. Ensure lockset displays a green flash (and no other lights).
b. Ensure outside lever retracts latch, the door opens, and that there is
no binding against lock case, wire harness or other obstructions.
• For units with a keypad, the following checks ply:
Insert test card marked PIN 1234 and retract:
a. Ensure lockset displays solid yellow light.
b. Type 1, 2, 3, 4 on keypad.
c. Ensure outside lever retracts latch, the door opens, and that there is
no binding against lock case, wire harness or other obstructions.
d. Test again with card marked PIN 5678.
e. Test again with card marked PIN 9090.
2. Any rapid yellow or rapid red flashing lights indicate a low power condition.
Check the battery voltage at the top of the battery pack to check for the required 9V.
If the voltage is correct, inspect the wiring for a possible short.
3. When you have completed the tests, close the door, ensuring latchbolt and deadbolt
fully extend into strike plate without binding.