background image

FIGURE 2

Note: Parts 1-18  

are pre-assembled. 

Expanded view  

is for parts 

identification, 

specification  

and replacement.

PARTS DIAGRAM

1

2

3

4

5

6
7

8

9

10

11

12

13

15
16
17

18

14

Summary of Contents for Bio Cube

Page 1: ... LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED WARRANTY ALL SUCH WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY CORALIFE IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY CORALIFE EXPRE...

Page 2: ...Central Garden Pet Co Franklin WI 53132 888 255 4527 coralifeproducts com Coralife is a registered trademark of Central Garden Pet Co 2011 Central Garden Pet Co Please read these instructions in their entirety before attempting to use this product Size 14 Instructions ...

Page 3: ...er from dripping onto the receptacle or plug A drip loop shown in figure below should be arranged by the user for each cord connecting an aquarium appliance to a receptacle The drip loop is that part of the cord below the level of the receptacle or the connector if an extension cord is used to prevent water traveling along the cord and coming in contact with the receptacle If the plug or receptacl...

Page 4: ...he weight of a filled aquarium are suspended can rock or sway can sag or on wheels or allows the aquarium to over hang These could cause the aquarium to leak crack or even fall over if a top heavy situation is created 5 Aquarium supports that are less than 12 wide front and back should be fastened or tethered to a wall to prevent a top heavy or unstable condition 6 Do not allow water pump to opera...

Page 5: ...FIGURE 2 Note Parts 1 18 are pre assembled Expanded view is for parts identification specification and replacement PARTS DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 18 14 ...

Page 6: ...low Tray 11 Output Elbow Attachment 12 Output Discharge Nozzle 13 Flexible Tubing 5 I D tubing 14 Bio Balls 15 Bio Ball Strainer 16 Water Pump 17 Sponge Filter 18 Glass Aquarium PRODUCT SPECIFICATION BioCube Size 14 Dimension 15 l x 15 5 w x 16 5 h Canopy Lighting 1 24 Watt True Actinic 03 Blue Straight Pin 1 24 Watt 10 000K Daylight Straight Pin 1 75 Watt Lunar Blue LED Bar Extra receptor for 1 a...

Page 7: ...rminal screw and the like extending from the adapter must be fastened to a permanent ground such as a grounded outlet box 1 Plug temporary adapter into two pole outlet Figure 5 2 Insert screw through rigid ear on temporary adapter and into grounded outlet box Figure 6 Power Strip Setup 1 If using a powerstrip the ground connector must be plugged into a receptacle controlled by a GFI ground fault i...

Page 8: ...ry Filter Assembly 1 Make sure that the BioCube filter cartridge is properly inserted at the 1st chamber of the wet dry section Figure 8 2 Make sure that the overflow tray bio balls and bio ball strainer are properly placed inside the 2nd chamber of the wet dry section 3 Make sure that the sponge filter is correctly placed in the 3rd chamber of the wet dry section 4 Make sure that the water pump i...

Page 9: ...r saltwater freshwater Make sure water is at room temperature to prevent condensation 4 Open canopy and slowly add water to the aquarium Make sure to fill aquarium up to the lower edge of the top moulding Figure 11 5 Plug water pump power cord into an outlet or power source Pump will raise water level in aquarium section and drain into wet dry section Figure 12 OPERATION FIGURE 10 FIGURE 11 FIGURE...

Page 10: ...the aquarium through the output discharge nozzle Precautions For optimal filter performance 1 Do not block or obstruct surface intake and bottom intake 2 Do not block or obstruct output discharge nozzle 3 Perform scheduled maintenance on filter cartridge 4 Observe scheduled maintenance on water pump 5 Make sure to perform scheduled water changes and BioCube filtration maintenance OPERATION FIGURE ...

Page 11: ... terrycloth 3 Inspect filtration system for clogging and excessive accumulation of debris Clean and remove debris from surface bottom intake and overflow tray Rinse parts if needed Note Do not clean bio balls Cleaning the bio media is harmful to beneficial nitrifying bacteria needed to break down ammonia and nitrites Monthly Maintenance 1 Remove used filter cartridge and discard Figure 19 Replace ...

Page 12: ...eplace silicon retaining band onto lamp clip to secure the compact fluorescent lamp 7 Attach light lens cover to canopy MAINTENANCE FIGURE 21 Pump Housing Pump Impeller Stainless Steel Shaft and Outlet Pump Cover FIGURE 22 Polished Reflector Compact Fluorescent Endcaps Compact Fluorescent Lamps Silicon Retaining Bands LED Lamps Lamp Clips Screws 4 Light Lens Cover FIGURE 24 FIGURE 23 LED Contact L...

Reviews: