Revision 01
June 2, 1997
Section 363-719-102
PG-Flex FCS-719
PairGain Engineering - Plant Series
Page 25
8.7
Subscriber Lines.
Connect the subscriber circuits to the wire-wrap terminations (Figure 9):
1
For PG-Flex system 1, wire-wrap CO switch subscriber circuit to the Tip and Ring pairs on P1
termination points. Refer to Table 13.
2
Repeat step 1 for each system installed, using the Tip and Ring pin pairs on P2 for system 2, P3
for system 3, and P4 for system 4.
Figure 9. Subscriber Line Termination
8.8
Auxiliary Power Pairs.
When PG-Flex is used with a doubler, wire the auxiliary power pairs to
the COT shelf (Figure 10) as follows:
1
Wire-wrap auxiliary power pair 1 to PWR_1_T1 (Tip) and PWR_1_R1 (Ring) for
system 1.
2
Wire-wrap auxiliary power pair 2 to PWR_2_T2 (Tip) and PWR_2_R2 (Ring) for
system 2.
3
Repeat steps 1 and 2 when required for systems 2, 3, and 4.
Figure 10. Installing the Auxiliary Power Pairs