Section 363-718-102
May 30, 1997
Revision 01
Page 24
PairGain Engineering - Plant Series
PG-Flex FCS-718
8.3
HDSL Lines.
Connect the HDSL lines (Figure 6):
1
For System 1 installation:
a
Connect the HDSL Pair #1 on System 1 onto wire-wrap pins HDSL_T1 (Tip1) and
HDSL_R1 (Ring1) on the COT shelf.
b
Connect the HDSL Pair #2 on System 1 onto wire-wrap pins HDSL_T2 (Tip2) and
HDSL_R2 (Ring2) on the COT shelf.
2
For System 2 installation:
a
Connect HDSL Pair #1 on System 2 onto wire-wrap pins HDSL_T1 (Tip1) and HDSL_R1
(Ring1) on the COT shelf.
b
Connect HDSL Pair #2 on System 2 onto wire-wrap pins HDSL_T2 (Tip2) and HDSL_R2
(Ring2) on the COT shelf.
Figure 6. Connecting the HDSL Lines