150-412-181-01
March 31, 1998
Revision 01
HRU-412 List 8A
PairGain Engineering - Plant Series
19
Logging On and Using the Menus
The HRU-412 List 8A supports local and remote log on. Local log on
connects the Craft port (RS-232 connector) to the HRU-412 List 8A internal
database. Remote log on connects the HRU-412 List 8A to the HLU using the
HDSL Embedded Operation Channel (EOC) as the data link between the two
units. Remote log on creates menus and screens at the HRU-412 List 8A that
are identical to those at the HLU. See the appropriate line unit technical
practice for more information about the menus and screens.
Initial log on to the HRU-412 List 8A is local for non-doubler applications.
When the HRU-412 List 8A is not connected to an HLU, the displayed menus
and screens are those from the HRU-412 List 8A internal database.
When the HRU-412 List 8A is connected to an HLU and doublers are in use,
the port interface resets to remote when the two units synchornize. The
remote log off option on the Main Menu (shown when in remote mode only)
allows the termination of a remote session. Terminating a remote log on
allows other units (such as a doubler) to log on through the Craft port.
Terminating each remote session before beginning another is necessary
because a HiGain circuit can support the log on of only one unit at a time. An
active session for any unit prevents simultaneous sessions for any other
circuit.
This section shows you how to log on and access the menus and screens using
the ASCII terminal.
1
Press the spacebar several times to activate the autobaud feature and to
display the logon screen. When using doublers, the remote log on screen
displays when the HRU-412 List 8A and the HLU synchronize. See
.