Gas Type Selection may be set from the parameter menu. Factory default value is NG.
• You may enter the parameter menu if you bring POT1 from OFF position to ON position
three times within two seconds.
• The SET symbol and the real parameter value (gas type selection) is displayed when you enter.
• POT2 is used for gas type selection. The gas type that corresponds to the current position of
POT2 flashes on the screen. The selections as per the position of POT2 are as follows:
ON/OFF setting is performed with POT1.
10.1. RESET
10.2. PARAMETER MENU
POT1 trimmer range
Effect
0 - 25%
26 - 100%
OFF
ON
POT1 trimmer range
Effect
0 - 100%
DHW mode active, DHW SET value is set
between minimum - maximum values
DHW SET temperature value is displayed on the screen and DHW mode symbol flashes if
POT2 is rotated. Normal operating parameters are displayed again after 5 seconds when the
setting is stopped.
•
The selection is confirmed by bringing the switch from OFF position to ON position three
times within two seconds.
•
Changes are cancelled by by bringing the switch from OFF position to ON position
1 or 2 times.
Water heater is reset by bringing POT1 from OFF position to ON position.
The SET symbol flashes with the following indicators
when gas type is being selected:
NG (Natural Gas): nG
LPG : LG
LPG
NG
Summary of Contents for Nixa12
Page 1: ...Nixa12 Hermetik Şofben Kullanım ve Montaj Kılavuzu copa com tr ...
Page 15: ...COPA Nixa12 Hermetik Şofben Kullanım ve Montaj Kılavuzu 12 12 0 Elektronik Kart Devre Şeması ...
Page 16: ...COPA Nixa12 Hermetik Şofben Kullanım ve Montaj Kılavuzu 13 12 0 Elektronik Kart Devre Şeması ...
Page 23: ...Nixa12 Hermetic Water Heater User and Installation Manual copa com tr ...
Page 39: ......
Page 41: ...copa com tr copaisisistemleri M ü ş t e r i H i z m e t l e r i ...