COPA Eomix Wall Hung Gas Boiler User and Installation Manual
1.2. Place Selections
• The possible places where the
appliance can be installaed are
seen on Drawings 1.2.1 ve 1.2.2.
27
The Critical Dimensions to the
Installation of the Product.
The Wall and The Chimney’s
Installation Dimensions of
The Product
• The boiler can not be installed
to open balcony, on the
chimney holes, through aeration
halls.
• The max. natural wing speed is
10 m/s, for chimney outlets.
• There should be 100 mm gab on
the sides, 200 mm gab on
bottom and top if installed to a
gardrobe.
• There should be min. 100 mm
from the walls and side and
front surfaces of the boiler as
hot areas should be cared.
• There should be min.
500 mm clearence from
inflamable materials.
• The maintenance which includes
the cleaning of the boiler
(cleaning of inside dusts, fan
motor, heat exchanger fins,
water filters) is adviced to be
done by annually with the COPA
authorised services.
Minimum Distances Are Below As CM
A -
Under a window
B -
Under any aeration places
C -
Under rain system
D -
Under balcony
E -
Near to window
F -
Near to aeration places
G -
Near any vertical/
horizontal pipes
H -
From the corner of building
İ -
From inlet corners
J -
From floor
K -
The vertical distance
betwen 2 chimney
L -
The horizontal distance
between 2 chimney
60 cm
60 cm
30 cm
30 cm
40 cm
60 cm
60 cm
30 cm
100 cm
150 cm
100 cm
180 cm
Drawing 1.2.1
Drawing 1.2.2
E
H
A
B
G
D
I
C
F
min.10 cm
190 cm
min.10 cm
min.30 cm
2º