2
Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
VTO2202F-P
Module
802.3af PoE
Tamper Switch
Sounds an alarm in the event that the VTO unit is tampered with
Network Connection
Connect the supplied RJ45 adapter cable to this port
+12v
Used when not powering the VTO via PoE, connect the 12v or 24v DC positive supply to this
terminal
GND
Ground connection for 12v DC negative supply and other inputs
12v Out
DC 12v continuous output for auxiliary device (100mA max)
Door Button
Input to connect a switch such as a push button for releasing the door lock
Door FB
Input for door contact to check if the door is closed before engaging lock
Door NO/NC/COM
Relay output used when unlocking door
RS485 A/B
RS485 Bus for connecting secondary lock controller DEE1010B
Master VTH PoE Monitor
When configuring a home VDP system, all devices should first be connected together. Usually, this is done by connecting both the
camera unit (VTO) and monitor(s)(VTH) to a switch and or network, see examples below:
Example 1 - Single Household
Example 2 - Apartment System
VDP SYSTEM CONFIGURATIONS
VTO CONNECTIONS
PoE
Switch
Tamper
Switch
NET
Network
Connection
Inputs &
Outputs
GND
ALARM_COM
DOOR_FB
DOOR BUTT
ON
ALARM_ON
GND
DOOR_NC DOOR_COM DOOR_NO
12V_OUT
RS485_B RS485_A
EOC1(+12) EOC1(GND)
VTO6221E-P
Module
802.3af PoE
Master VTH PoE Monitor
PoE
Switch
Optional
Extension monitor
Master VTH PoE Monitor
802.3af PoE
802.3af PoE
802.3af PoE